Evidence-linked product lifecycle intelligenceSUPPORT · SECURITY · RETIREMENT
← Search results
CVE-LINKED INVENTORY6 SECURITY RECORDS

Schneider Electric

ClearSCADA

Affected and fixed version statements observed in the public BlackTree CVE catalogue. These statements describe vulnerability scope, not publisher support entitlement.

Lifecycle evidence status

This identity is present in BlackTree CVE records, but no product-specific publisher support or retirement history is currently registered in Lifecycle.

A missing support date does not mean the product is supported. CVE publication dates and affected-version ranges must not be interpreted as EOL dates.

CVE-observed version history

CVEPublishedAffected versionsFixed version informationPublisher evidence
CVE-2017-6021 14 May 2018 2014 R1 (build 75.5210) and prior; 2014 R1.1 (build 75.5387) and prior; 2015 R1 (build 76.5648) and prior; 2015 R2 (build 77.5882) and prior No fixed version is explicitly recorded in the structured CVE data. Use CVE record
CVE-2017-9962 25 Sep 2017 2017, 2015 R2, 2015 R1.1, 2015 R1 and all prior versions No fixed version is explicitly recorded in the structured CVE data. Update reference ↗
CVE-2014-5413 18 Sep 2014 ClearSCADA: 2010 R3 (build 72.4560), 2010 R3.1 (build 72.4644); SCADA Expert ClearSCADA: 2013 R1 (build 73.4729), 2013 R1.1 (build 73.4832), 2013 R1.1a (build 73.4903), 2013 R1.2 (build 73.4955), 2013 R2 (build 74.5094), 2013 R2.1 (build 74.5192), 2014 R1 (build 75.5210) ClearSCADA: 2010 R3.2; SCADA Expert ClearSCADA: 2014 R1.1 Update reference ↗
CVE-2014-5412 18 Sep 2014 ClearSCADA: 2010 R3 (build 72.4560), 2010 R3.1 (build 72.4644); SCADA Expert ClearSCADA: 2013 R1 (build 73.4729), 2013 R1.1 (build 73.4832), 2013 R1.1a (build 73.4903), 2013 R1.2 (build 73.4955), 2013 R2 (build 74.5094), 2013 R2.1 (build 74.5192), 2014 R1 (build 75.5210) ClearSCADA: 2010 R3.2; SCADA Expert ClearSCADA: 2014 R1.1 Update reference ↗
CVE-2014-5411 18 Sep 2014 ClearSCADA: 2010 R3 (build 72.4560), 2010 R3.1 (build 72.4644); SCADA Expert ClearSCADA: 2013 R1 (build 73.4729), 2013 R1.1 (build 73.4832), 2013 R1.1a (build 73.4903), 2013 R1.2 (build 73.4955), 2013 R2 (build 74.5094), 2013 R2.1 (build 74.5192), 2014 R1 (build 75.5210) ClearSCADA: 2010 R3.2; SCADA Expert ClearSCADA: 2014 R1.1 Update reference ↗
CVE-2014-0779 14 Mar 2014 ClearSCADA: 2010 R2 (build 71.4165), 2010 R2.1 (build 71.4325), 2010 R3 (build 72.4560), 2010 R3.1 (build 72.4644); SCADA Expert ClearSCADA: 2013 R1 (build 73.4729), 2013 R1.1 (build 73.4832), 2013 R1.1a (build 73.4903), 2013 R1.2 (build 73.4955), 2013 R2 (build 74.5094) Schneider Electric recommends that customers using the vulnerable product versions to:; * Uninstall the Kepware driver in the vulnerable product versions and migrate to an external installation of KepServerEX V5.; * Guidance and assistance is available from Schneider Electric Technical Application Support at:; http://products.schneider-electric.us/products-services/services/automation-and-control-services/tel... http://products.schneider-electric.us/products-services/services/automation-and-control-services/telephone-and-software-support/telephone-support-service/ .; Kepware has confirmed this vulnerability is not present in KepServerEX V5.; The security announcement affecting the SCADA Expert ClearSCADA File Parsing Vulnerability is available here:; http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-024-01 . Update reference ↗

How this record is maintained

The CVE inventory is reconciled automatically from cve.blacktree.nl. Exact identity matches link to existing Lifecycle product or package histories. Unmatched products stay in a prioritised publisher-source research queue, and Lifecycle marks the date gap instead of inferring a support boundary from vulnerability data.