{"api_version":"v1","generated_at":"2026-10-09T08:25:00+00:00","product":{"cve_count":4,"evidence_gap_note":"This identity is present in BlackTree CVE records, but no product-specific publisher support or retirement history is currently registered in Lifecycle.","id":"security:cve-schneider-electric-clearscada-966d5332ebeb","lifecycle_state":"evidence_gap","linked_lifecycle_url":null,"name":"ClearSCADA","next_cursor":null,"observations":[{"affected":"2014 R1 (build 75.5210) and prior; 2014 R1.1 (build 75.5387) and prior; 2015 R1 (build 76.5648) and prior; 2015 R2 (build 77.5882) and prior","affected_versions_present":true,"cve_id":"CVE-2017-6021","cve_url":"https://cve.blacktree.nl/cve/CVE-2017-6021","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2024-09-16T22:56:53.661Z","patch_url":"","primary_source":"","published":"2018-05-14T14:00:00.000Z"},{"affected":"2017, 2015 R2, 2015 R1.1, 2015 R1 and all prior versions","affected_versions_present":true,"cve_id":"CVE-2017-9962","cve_url":"https://cve.blacktree.nl/cve/CVE-2017-9962","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2024-09-16T19:15:45.794Z","patch_url":"http://www.schneider-electric.com/en/download/document/SEVD-2017-264-01/","primary_source":"","published":"2017-09-25T19:00:00.000Z"},{"affected":"ClearSCADA: 2010 R3 (build 72.4560), 2010 R3.1 (build 72.4644); SCADA Expert ClearSCADA: 2013 R1 (build 73.4729), 2013 R1.1 (build 73.4832), 2013 R1.1a (build 73.4903), 2013 R1.2 (build 73.4955), 2013 R2 (build 74.5094), 2013 R2.1 (build 74.5192), 2014 R1 (build 75.5210)","affected_versions_present":true,"cve_id":"CVE-2014-5413","cve_url":"https://cve.blacktree.nl/cve/CVE-2014-5413","fixed":"ClearSCADA: 2010 R3.2; SCADA Expert ClearSCADA: 2014 R1.1","last_modified":"2025-11-04T22:59:00.297Z","patch_url":"https://www.cisa.gov/news-events/ics-advisories/icsa-14-259-01a","primary_source":"","published":"2014-09-18T10:00:00.000Z"},{"affected":"ClearSCADA: 2010 R3 (build 72.4560), 2010 R3.1 (build 72.4644); SCADA Expert ClearSCADA: 2013 R1 (build 73.4729), 2013 R1.1 (build 73.4832), 2013 R1.1a (build 73.4903), 2013 R1.2 (build 73.4955), 2013 R2 (build 74.5094), 2013 R2.1 (build 74.5192), 2014 R1 (build 75.5210)","affected_versions_present":true,"cve_id":"CVE-2014-5412","cve_url":"https://cve.blacktree.nl/cve/CVE-2014-5412","fixed":"ClearSCADA: 2010 R3.2; SCADA Expert ClearSCADA: 2014 R1.1","last_modified":"2025-11-04T22:56:12.970Z","patch_url":"https://www.cisa.gov/news-events/ics-advisories/icsa-14-259-01a","primary_source":"","published":"2014-09-18T10:00:00.000Z"},{"affected":"ClearSCADA: 2010 R3 (build 72.4560), 2010 R3.1 (build 72.4644); SCADA Expert ClearSCADA: 2013 R1 (build 73.4729), 2013 R1.1 (build 73.4832), 2013 R1.1a (build 73.4903), 2013 R1.2 (build 73.4955), 2013 R2 (build 74.5094), 2013 R2.1 (build 74.5192), 2014 R1 (build 75.5210)","affected_versions_present":true,"cve_id":"CVE-2014-5411","cve_url":"https://cve.blacktree.nl/cve/CVE-2014-5411","fixed":"ClearSCADA: 2010 R3.2; SCADA Expert ClearSCADA: 2014 R1.1","last_modified":"2025-11-04T22:53:17.900Z","patch_url":"https://www.cisa.gov/news-events/ics-advisories/icsa-14-259-01a","primary_source":"","published":"2014-09-18T10:00:00.000Z"},{"affected":"ClearSCADA: 2010 R2 (build 71.4165), 2010 R2.1 (build 71.4325), 2010 R3 (build 72.4560), 2010 R3.1 (build 72.4644); SCADA Expert ClearSCADA: 2013 R1 (build 73.4729), 2013 R1.1 (build 73.4832), 2013 R1.1a (build 73.4903), 2013 R1.2 (build 73.4955), 2013 R2 (build 74.5094)","affected_versions_present":true,"cve_id":"CVE-2014-0779","cve_url":"https://cve.blacktree.nl/cve/CVE-2014-0779","fixed":"Schneider Electric recommends that customers using the vulnerable product versions to:; * Uninstall the Kepware driver in the vulnerable product versions and migrate to an external installation of KepServerEX V5.; * Guidance and assistance is available from Schneider Electric Technical Application Support at:; http://products.schneider-electric.us/products-services/services/automation-and-control-services/tel... http://products.schneider-electric.us/products-services/services/automation-and-control-services/telephone-and-software-support/telephone-support-service/ .; Kepware has confirmed this vulnerability is not present in KepServerEX V5.; The security announcement affecting the SCADA Expert ClearSCADA File Parsing Vulnerability is available here:; http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-024-01 .","last_modified":"2025-09-24T21:33:37.552Z","patch_url":"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-024-01","primary_source":"","published":"2014-03-14T10:00:00.000Z"}],"source_generated_at":"2026-10-09T06:17:25.511Z","vendor":"Schneider Electric"}}