Evidence-linked product lifecycle intelligenceSUPPORT · SECURITY · RETIREMENT
← Search results
CVE-LINKED INVENTORY1 SECURITY RECORD

M&M Software

fdtCONTAINER Component

Affected and fixed version statements observed in the public BlackTree CVE catalogue. These statements describe vulnerability scope, not publisher support entitlement.

Lifecycle evidence status

This identity is present in BlackTree CVE records, but no product-specific publisher support or retirement history is currently registered in Lifecycle.

A missing support date does not mean the product is supported. CVE publication dates and affected-version ranges must not be interpreted as EOL dates.

CVE-observed version history

CVEPublishedAffected versionsFixed version informationPublisher evidence
CVE-2020-12525 22 Jan 2021 unspecified < 3.5; 3.5 < 3.5.20304.x; 3.6 < 3.6.20304.x; unspecified < 4.5; 4.5 < 4.5.20304.x; 4.6 < 4.6.20304.x; 3; unspecified ≤ 5.0.5.31 EcoStruxure™ Control Expert V15.1, available for download below, includes a fix for CVE-2021-22778, CVE-2021-22780, CVE-2021-22781, CVE-2021-22782, CVE-2020-12525: https://www.se.com/ww/en/download/document/EcoStruxureControlExpert_V15.1/ *Upgrading to EcoStruxure™ Control Expert V15.1 is the first step in a two stepsprocess to fully address CVE-2021-22779. To fully address this issue a firmwarerelease will follow. Important Note: •The fix is provided through the additional feature “file encryption”, forfurther information on the feature and how to set it up please refers to thechapter “file encryption” of the help file available in the EcoStruxure™Control Expert v15.0 SP1. •This feature is proposed by default when creating a new project. •This feature is also available, after selecting “project” in structural view, inthe “Edit/ Properties/ Project & Controller Protection” menu. •For new projects: oCustomers are recommended to apply this feature to all newprojects. •For existing projects: oCustomers are recommended to apply this feature to the existingprojects coming from trusted source. For .sta project files, as areminder, project modification can be done in connected mode toprevent desynchronization and keep the controller in RUN state. •It is possible to set a security level specific to the Derived Function Blocks(DFB) in addition to the file encryption feature. Please refer to the chapter"How to protect a DFB type" in the EcoStruxure™ Control Expert help filefor further information. •Customers are recommended to share project files only when configuredwith the encryption feature described above. If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit. These mitigations also reduce the risk of exploit for CVE-2021-22779 on all versions of EcoStruxure™ Control Expert, including V15.1: •Store the project files in a secure storage and restrict the access to onlytrusted users •When exchanging files over the network, use secure communicationprotocols •Encrypt project files when stored •Only open project files received from trusted source •Compute a hash of the project files and regularly check the consistency ofthis hash to verify the integrity before usage. •Harden the workstation running EcoStruxure™ Control Expert or Unity Pro Customers using Unity Pro should strongly consider migrating to EcoStruxure™ Control Expert. Please contact your local Schneider Electric technical support for more information. Update reference ↗

How this record is maintained

The CVE inventory is reconciled automatically from cve.blacktree.nl. Exact identity matches link to existing Lifecycle product or package histories. Unmatched products stay in a prioritised publisher-source research queue, and Lifecycle marks the date gap instead of inferring a support boundary from vulnerability data.