CVE-observed version history
| CVE | Published | Affected versions | Fixed version information | Publisher evidence |
|---|---|---|---|---|
| CVE-2025-11044 | 19 Jan 2026 | 4 < R4.93; 6 < 6.5 | The problem is corrected in the following product versions: - Automation Runtime 6 versions >= 6.5 - Automation Runtime 4 versions >= R4.93 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. | Update reference ↗ |
| CVE-2025-11498 | 14 Oct 2025 | Automation Runtime: 6.0 < 6.4, 4 | The problem is corrected in Automation Runtime 6.4. The System Diagnostic Manager (SDM) is disabled by default in Automation Runtime 6 and is not intended be enabled on active systems located outside properly secured production networks or in facilities lacking adequate physical and logical access controls to prevent any form of unauthorized interaction. For customers who use SDM on their systems, B&R recommends applying the update based on risk assessment at the earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. | Update reference ↗ |
| CVE-2025-3449 | 7 Oct 2025 | Automation Runtime: 6.0 < 6.4, 4 | The problem is corrected in Automation Runtime 6.4. The System Diagnostic Manager (SDM) is disabled by default in Automation Runtime 6 and is not intended be enabled on active systems located outside properly secured production networks or in facilities lacking adequate physical and logical access controls to prevent any form of unauthorized interaction. For customers who use SDM on their systems, B&R recommends applying the update based on risk assessment at the earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. | Update reference ↗ |
| CVE-2025-3448 | 7 Oct 2025 | Automation Runtime: 6.0 < 6.4, 4 | The problem is corrected in Automation Runtime 6.4. The System Diagnostic Manager (SDM) is disabled by default in Automation Runtime 6 and is not intended be enabled on active systems located outside properly secured production networks or in facilities lacking adequate physical and logical access controls to prevent any form of unauthorized interaction. For customers who use SDM on their systems, B&R recommends applying the update based on risk assessment at the earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. | Update reference ↗ |
| CVE-2025-3450 | 7 Oct 2025 | 6.0 < 6.3; 4.0 < Q4.93 | The problem is corrected in Automation Runtime versions 6.3 and Q4.93. The System Diagnostic Manager (SDM) is disabled by default in Automation Runtime 6 and is not in-tended be enabled on active systems located outside properly secured production networks or in facilities lacking adequate physical and logical access controls to prevent any form of unauthorized interaction. For customers who use SDM on their systems, B&R recommends applying the update at the earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual. | Update reference ↗ |
| CVE-2024-8603 | 15 Jan 2025 | 6.0 < 6.1; 4.0; 5.0 | The problem is corrected in the following product versions: B&R Automation Runtime version 6.1. B&R mapp View 6.1. B&R recommends that customers apply the update at their earliest convenience if B&R Automation Runtime or B&R mapp View is used to generate self-signed certificates on production machines. | Update reference ↗ |
| CVE-2024-5801 | 10 Aug 2024 | < 6.0 | No fixed version is explicitly recorded in the structured CVE data. | Use CVE record |
| CVE-2024-5800 | 10 Aug 2024 | < 6.0.0 | No fixed version is explicitly recorded in the structured CVE data. | Use CVE record |
| CVE-2023-6028 | 5 Feb 2024 | 14.0 < 14.93 | No fixed version is explicitly recorded in the structured CVE data. | Use CVE record |
| CVE-2024-0323 | 5 Feb 2024 | 14.0 < 14.93 | No fixed version is explicitly recorded in the structured CVE data. | Use CVE record |
How this record is maintained
The CVE inventory is reconciled automatically from cve.blacktree.nl. Exact identity matches link to existing Lifecycle product or package histories. Unmatched products stay in a prioritised publisher-source research queue, and Lifecycle marks the date gap instead of inferring a support boundary from vulnerability data.