{"api_version":"v1","generated_at":"2026-10-05T23:55:00+00:00","product":{"cve_count":69,"evidence_gap_note":"This identity is present in BlackTree CVE records, but no product-specific publisher support or retirement history is currently registered in Lifecycle.","id":"security:cve-siemens-telecontrol-server-basic-98f07b57030d","lifecycle_state":"evidence_gap","linked_lifecycle_url":null,"name":"TeleControl Server Basic","next_cursor":"djE6NTA","observations":[{"affected":"< V3.1.2.4","affected_versions_present":true,"cve_id":"CVE-2025-40942","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-40942","fixed":"Update to V3.1.2.4 or later version","last_modified":"2026-01-13T17:36:00.499Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-192617.html","primary_source":"","published":"2026-01-13T09:44:04.669Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-29931","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-29931","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:43:50.005Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-395348.html","primary_source":"","published":"2025-04-17T11:05:57.612Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32872","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32872","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:14:36.389Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:39:00.326Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32871","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32871","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:14:44.243Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:58.559Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32870","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32870","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:14:51.304Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:57.182Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32869","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32869","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:14:58.053Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:55.788Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32868","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32868","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:15:05.868Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:54.410Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32867","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32867","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:15:15.038Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:53.028Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32866","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32866","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:15:24.860Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:51.620Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32865","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32865","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:15:32.335Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:50.158Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32864","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32864","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:15:39.703Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:48.731Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32863","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32863","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:15:48.108Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:47.349Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32862","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32862","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:15:56.995Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:45.949Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32861","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32861","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:16:05.840Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:44.533Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32860","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32860","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:16:13.625Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:43.055Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32859","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32859","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:16:21.247Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:41.565Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32858","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32858","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:16:28.322Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:40.150Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32857","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32857","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:16:35.577Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:38.756Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32856","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32856","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:16:42.599Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:37.361Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32855","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32855","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:16:50.126Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:35.963Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32854","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32854","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:16:57.586Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:34.488Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32853","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32853","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:17:05.765Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:33.094Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32852","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32852","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:17:12.534Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:31.692Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32851","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32851","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:17:20.517Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:30.324Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32850","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32850","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:17:28.042Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:28.950Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32849","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32849","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:17:35.028Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:27.510Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32848","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32848","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:17:42.633Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:26.132Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32847","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32847","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:17:50.095Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:24.769Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32846","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32846","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:17:57.268Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:23.275Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32845","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32845","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:18:04.695Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:20.710Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32844","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32844","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:18:13.396Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:19.293Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32843","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32843","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:18:20.843Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:17.866Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32842","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32842","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:18:28.186Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:16.457Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32841","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32841","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:18:37.206Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:14.980Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32840","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32840","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:18:44.164Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:13.513Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32839","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32839","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:18:52.300Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:11.668Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32838","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32838","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:19:01.016Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:10.118Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32837","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32837","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:19:09.202Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:08.705Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32836","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32836","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:19:16.680Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:07.241Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32835","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32835","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:19:23.285Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:05.783Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32834","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32834","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:19:31.356Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:04.036Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32833","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32833","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:19:38.929Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:02.590Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32832","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32832","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-16T18:40:32.614Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:38:00.996Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32831","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32831","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:19:48.946Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:37:59.574Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32830","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32830","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:19:58.370Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:37:58.050Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32829","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32829","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:20:07.329Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:37:56.625Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32828","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32828","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-17T14:20:13.879Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:37:55.116Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32827","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32827","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-16T18:46:42.199Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:37:53.691Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32826","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32826","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-16T18:48:46.448Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:37:52.113Z"},{"affected":"< V3.1.2.2","affected_versions_present":true,"cve_id":"CVE-2025-32825","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-32825","fixed":"Update to V3.1.2.2 or later version","last_modified":"2025-04-16T18:51:30.717Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-443402.html","primary_source":"","published":"2025-04-16T17:37:50.627Z"}],"source_generated_at":"2026-10-05T06:20:29.126Z","vendor":"Siemens AG"}}