{"api_version":"v1","generated_at":"2026-10-10T05:10:00+00:00","product":{"cve_count":3,"evidence_gap_note":"This identity is present in BlackTree CVE records, but no product-specific publisher support or retirement history is currently registered in Lifecycle.","id":"security:cve-siemens-scalance-w721-1-rj45-cf4e7a817c73","lifecycle_state":"evidence_gap","linked_lifecycle_url":null,"name":"SCALANCE W721-1 RJ45","next_cursor":null,"observations":[{"affected":"< *","affected_versions_present":true,"cve_id":"CVE-2024-30189","cve_url":"https://cve.blacktree.nl/cve/CVE-2024-30189","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2024-08-02T01:25:03.406Z","patch_url":"","primary_source":"","published":"2024-04-09T08:34:40.217Z"},{"affected":"SCALANCE W721-1 RJ45: < V6.6.0; SCALANCE W722-1 RJ45: < V6.6.0; SCALANCE W734-1 RJ45: < V6.6.0; SCALANCE W734-1 RJ45 (USA): < V6.6.0; SCALANCE W738-1 M12: < V6.6.0; SCALANCE W748-1 M12: < V6.6.0; SCALANCE W748-1 RJ45: < V6.6.0; SCALANCE W761-1 RJ45: < V6.6.0; SCALANCE W774-1 M12 EEC: < V6.6.0; SCALANCE W774-1 RJ45: < V6.6.0; SCALANCE W774-1 RJ45 (USA): < V6.6.0; SCALANCE W778-1 M12: < V6.6.0; SCALANCE W778-1 M12 EEC: < V6.6.0; SCALANCE W778-1 M12 EEC (USA): < V6.6.0; SCALANCE W786-1 RJ45: < V6.6.0; SCALANCE W786-2 RJ45: < V6.6.0; SCALANCE W786-2 SFP: < V6.6.0; SCALANCE W786-2IA RJ45: < V6.6.0; SCALANCE W788-1 M12: < V6.6.0; SCALANCE W788-1 RJ45: < V6.6.0; SCALANCE W788-2 M12: < V6.6.0; SCALANCE W788-2 M12 EEC: < V6.6.0; SCALANCE W788-2 RJ45: < V6.6.0","affected_versions_present":true,"cve_id":"CVE-2020-26140","cve_url":"https://cve.blacktree.nl/cve/CVE-2020-26140","fixed":"Update to V6.6.0 or later version","last_modified":"2026-10-08T21:14:07.950Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-019200.html","primary_source":"","published":"2021-05-11T19:34:42.000Z"},{"affected":"SCALANCE W721-1 RJ45: < V6.6.0; SCALANCE W722-1 RJ45: < V6.6.0; SCALANCE W734-1 RJ45: < V6.6.0; SCALANCE W734-1 RJ45 (USA): < V6.6.0; SCALANCE W738-1 M12: < V6.6.0; SCALANCE W748-1 M12: < V6.6.0; SCALANCE W748-1 RJ45: < V6.6.0; SCALANCE W761-1 RJ45: < V6.6.0; SCALANCE W774-1 M12 EEC: < V6.6.0; SCALANCE W774-1 RJ45: < V6.6.0; SCALANCE W774-1 RJ45 (USA): < V6.6.0; SCALANCE W778-1 M12: < V6.6.0; SCALANCE W778-1 M12 EEC: < V6.6.0; SCALANCE W778-1 M12 EEC (USA): < V6.6.0; SCALANCE W786-1 RJ45: < V6.6.0; SCALANCE W786-2 RJ45: < V6.6.0; SCALANCE W786-2 SFP: < V6.6.0; SCALANCE W786-2IA RJ45: < V6.6.0; SCALANCE W788-1 M12: < V6.6.0; SCALANCE W788-1 RJ45: < V6.6.0; SCALANCE W788-2 M12: < V6.6.0; SCALANCE W788-2 M12 EEC: < V6.6.0; SCALANCE W788-2 RJ45: < V6.6.0; SCALANCE WAM763-1: < V1.2.0; SCALANCE WAM766-1: < V1.2.0; SCALANCE WAM766-1 (US): < V1.2.0; SCALANCE WAM766-1 EEC: < V1.2.0; SCALANCE WAM766-1 EEC (US): < V1.2.0; SCALANCE WUM763-1: < V1.2.0; SCALANCE WUM766-1: < V1.2.0; SCALANCE WUM766-1 (USA): < V1.2.0","affected_versions_present":true,"cve_id":"CVE-2020-26144","cve_url":"https://cve.blacktree.nl/cve/CVE-2020-26144","fixed":"Update to V6.6.0 or later version","last_modified":"2026-10-08T21:14:02.978Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-019200.html","primary_source":"","published":"2021-05-11T19:33:04.000Z"}],"source_generated_at":"2026-10-09T06:17:25.511Z","vendor":"Siemens"}}