{"api_version":"v1","generated_at":"2026-10-09T10:40:00+00:00","product":{"cve_count":151,"evidence_gap_note":"This identity is present in BlackTree CVE records, but no product-specific publisher support or retirement history is currently registered in Lifecycle.","id":"security:cve-siemens-jt2go-8e7433efaca6","lifecycle_state":"evidence_gap","linked_lifecycle_url":null,"name":"JT2Go","next_cursor":"djE6NTA","observations":[{"affected":"< V2406.0003","affected_versions_present":true,"cve_id":"CVE-2024-41902","cve_url":"https://cve.blacktree.nl/cve/CVE-2024-41902","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2024-10-08T18:03:27.584Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-626178.html","primary_source":"","published":"2024-10-08T08:40:18.170Z"},{"affected":"< V14.3.0.8; < V14.1.0.14; < V14.2.0.10; < V2312.0002","affected_versions_present":true,"cve_id":"CVE-2023-7066","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-7066","fixed":"Update to V14.1.0.14 or later version","last_modified":"2025-08-27T20:42:53.230Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-722010.html","primary_source":"","published":"2024-08-12T21:46:38.910Z"},{"affected":"< V2312.0001; < V14.1.0.13; < V14.2.0.10; < V14.3.0.7","affected_versions_present":true,"cve_id":"CVE-2024-34086","cve_url":"https://cve.blacktree.nl/cve/CVE-2024-34086","fixed":"Update to V14.1.0.13 or later version","last_modified":"2024-08-02T02:42:59.863Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-661579.html","primary_source":"","published":"2024-05-14T10:03:10.774Z"},{"affected":"< V2312.0001; < V14.1.0.13; < V14.2.0.10; < V14.3.0.7","affected_versions_present":true,"cve_id":"CVE-2024-34085","cve_url":"https://cve.blacktree.nl/cve/CVE-2024-34085","fixed":"Update to V14.1.0.13 or later version","last_modified":"2024-08-02T02:42:59.891Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-661579.html","primary_source":"","published":"2024-05-14T10:03:09.574Z"},{"affected":"< V2312.0005; < V14.2.0.12; < V14.3.0.10","affected_versions_present":true,"cve_id":"CVE-2024-32637","cve_url":"https://cve.blacktree.nl/cve/CVE-2024-32637","fixed":"Update to V14.2.0.12 or later version","last_modified":"2024-08-13T07:54:07.678Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-856475.html","primary_source":"","published":"2024-05-14T10:02:44.682Z"},{"affected":"< V2312.0005; < V14.2.0.12; < V14.3.0.10","affected_versions_present":true,"cve_id":"CVE-2024-32636","cve_url":"https://cve.blacktree.nl/cve/CVE-2024-32636","fixed":"Update to V14.2.0.12 or later version","last_modified":"2024-08-13T07:54:06.352Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-856475.html","primary_source":"","published":"2024-05-14T10:02:43.480Z"},{"affected":"< V2312.0005; < V14.2.0.12; < V14.3.0.10","affected_versions_present":true,"cve_id":"CVE-2024-32635","cve_url":"https://cve.blacktree.nl/cve/CVE-2024-32635","fixed":"Update to V14.2.0.12 or later version","last_modified":"2024-08-13T07:54:05.071Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-856475.html","primary_source":"","published":"2024-05-14T10:02:42.291Z"},{"affected":"< V2312.0004; < V35.1.254; < V36.0.207; < V36.1.147; < V14.2.0.12; < V14.3.0.9","affected_versions_present":true,"cve_id":"CVE-2024-26277","cve_url":"https://cve.blacktree.nl/cve/CVE-2024-26277","fixed":"Update to V14.2.0.12 or later version","last_modified":"2024-08-13T07:54:03.735Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-771940.html","primary_source":"","published":"2024-04-09T08:34:38.896Z"},{"affected":"< V2312.0004; < V35.1.254; < V36.0.207; < V36.1.147; < V14.2.0.12; < V14.3.0.9","affected_versions_present":true,"cve_id":"CVE-2024-26276","cve_url":"https://cve.blacktree.nl/cve/CVE-2024-26276","fixed":"Update to V14.2.0.12 or later version","last_modified":"2024-08-13T07:54:02.376Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-771940.html","primary_source":"","published":"2024-04-09T08:34:37.744Z"},{"affected":"< V2312.0004; < V35.1.254; < V36.0.207; < V36.1.147; < V14.2.0.12; < V14.3.0.9","affected_versions_present":true,"cve_id":"CVE-2024-26275","cve_url":"https://cve.blacktree.nl/cve/CVE-2024-26275","fixed":"Update to V14.2.0.12 or later version","last_modified":"2024-08-13T07:54:00.911Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-771940.html","primary_source":"","published":"2024-04-09T08:34:36.604Z"},{"affected":"All versions < V14.3.0.6; All versions < V13.3.0.13; All versions < V14.1.0.12; All versions < V14.2.0.9","affected_versions_present":true,"cve_id":"CVE-2023-51746","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-51746","fixed":"Update to V13.3.0.13 or later version","last_modified":"2024-09-04T15:14:05.889Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-794653.html","primary_source":"","published":"2024-01-09T10:00:18.333Z"},{"affected":"All versions < V14.3.0.6; All versions < V13.3.0.13; All versions < V14.1.0.12; All versions < V14.2.0.9","affected_versions_present":true,"cve_id":"CVE-2023-51745","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-51745","fixed":"Update to V13.3.0.13 or later version","last_modified":"2025-06-03T14:31:19.908Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-794653.html","primary_source":"","published":"2024-01-09T10:00:17.032Z"},{"affected":"All versions < V14.3.0.6; All versions < V13.3.0.13; All versions < V14.1.0.12; All versions < V14.2.0.9","affected_versions_present":true,"cve_id":"CVE-2023-51744","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-51744","fixed":"Update to V13.3.0.13 or later version","last_modified":"2025-06-09T20:32:57.525Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-794653.html","primary_source":"","published":"2024-01-09T10:00:15.708Z"},{"affected":"All versions < V14.3.0.6; All versions < V13.3.0.13; All versions < V14.1.0.12; All versions < V14.2.0.9","affected_versions_present":true,"cve_id":"CVE-2023-51439","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-51439","fixed":"Update to V13.3.0.13 or later version","last_modified":"2025-04-17T17:54:26.450Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-794653.html","primary_source":"","published":"2024-01-09T10:00:14.394Z"},{"affected":"< 13.2.0.7; 12.4 < 12.4.0.13; 13.1 < 13.1.0.8; 13.2 < 13.2.0.7; 13.3 < 13.3.0.1","affected_versions_present":true,"cve_id":"CVE-2021-38405","cve_url":"https://cve.blacktree.nl/cve/CVE-2021-38405","fixed":"Update to V13.2.0.7 or later version","last_modified":"2024-08-04T01:37:16.588Z","patch_url":"https://cert-portal.siemens.com/productcert/pdf/ssa-301589.pdf","primary_source":"","published":"2023-11-21T18:19:10.557Z"},{"affected":"All versions < V14.3.0.1; All versions < V13.3.0.12; All versions; All versions < V14.1.0.11; All versions < V14.2.0.6; All versions < V2201.0010; All versions < V2302.0004","affected_versions_present":true,"cve_id":"CVE-2023-38076","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-38076","fixed":"Update to V13.3.0.12 or later version","last_modified":"2024-08-02T17:30:13.747Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-278349.html","primary_source":"","published":"2023-09-12T09:32:20.160Z"},{"affected":"All versions < V14.3.0.1; All versions < V13.3.0.12; All versions; All versions < V14.1.0.11; All versions < V14.2.0.6; All versions < V2201.0010; All versions < V2302.0004","affected_versions_present":true,"cve_id":"CVE-2023-38075","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-38075","fixed":"Update to V13.3.0.12 or later version","last_modified":"2024-08-02T17:30:13.592Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-278349.html","primary_source":"","published":"2023-09-12T09:32:19.039Z"},{"affected":"All versions < V14.3.0.1; All versions < V13.3.0.12; All versions; All versions < V14.1.0.11; All versions < V14.2.0.6; All versions < V2201.0010; All versions < V2302.0004","affected_versions_present":true,"cve_id":"CVE-2023-38074","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-38074","fixed":"Update to V13.3.0.12 or later version","last_modified":"2024-08-02T17:30:14.057Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-278349.html","primary_source":"","published":"2023-09-12T09:32:17.948Z"},{"affected":"All versions < V14.3.0.1; All versions < V13.3.0.12; All versions; All versions < V14.1.0.11; All versions < V14.2.0.6; All versions < V2201.0010; All versions < V2302.0004","affected_versions_present":true,"cve_id":"CVE-2023-38073","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-38073","fixed":"Update to V13.3.0.12 or later version","last_modified":"2024-08-02T17:30:14.105Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-278349.html","primary_source":"","published":"2023-09-12T09:32:16.855Z"},{"affected":"All versions < V14.3.0.1; All versions < V13.3.0.12; All versions; All versions < V14.1.0.11; All versions < V14.2.0.6; All versions < V2201.0010; All versions < V2302.0004","affected_versions_present":true,"cve_id":"CVE-2023-38072","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-38072","fixed":"Update to V13.3.0.12 or later version","last_modified":"2024-08-02T17:30:13.939Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-278349.html","primary_source":"","published":"2023-09-12T09:32:15.739Z"},{"affected":"All versions < V14.3.0.1; All versions < V13.3.0.12; All versions; All versions < V14.1.0.11; All versions < V14.2.0.6; All versions < V2201.0010; All versions < V2302.0004","affected_versions_present":true,"cve_id":"CVE-2023-38071","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-38071","fixed":"Update to V13.3.0.12 or later version","last_modified":"2024-11-25T21:17:56.790Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-278349.html","primary_source":"","published":"2023-09-12T09:32:14.673Z"},{"affected":"All versions < V14.3.0.1; All versions < V13.3.0.12; All versions; All versions < V14.1.0.11; All versions < V14.2.0.6; All versions < V2201.0010; All versions < V2302.0004","affected_versions_present":true,"cve_id":"CVE-2023-38070","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-38070","fixed":"Update to V13.3.0.12 or later version","last_modified":"2024-08-02T17:30:14.028Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-278349.html","primary_source":"","published":"2023-09-12T09:32:13.603Z"},{"affected":"All versions < V14.2.0.5; All versions < V13.2.0.14; All versions < V14.1.0.10","affected_versions_present":true,"cve_id":"CVE-2023-38683","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-38683","fixed":"Update to V13.2.0.14 or later version","last_modified":"2024-10-11T13:16:08.622Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-131450.html","primary_source":"","published":"2023-08-08T09:20:48.395Z"},{"affected":"All versions < V14.2.0.5; All versions < V13.2.0.14; All versions < V14.1.0.10","affected_versions_present":true,"cve_id":"CVE-2023-38682","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-38682","fixed":"Update to V13.2.0.14 or later version","last_modified":"2024-10-11T13:17:25.296Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-131450.html","primary_source":"","published":"2023-08-08T09:20:47.299Z"},{"affected":"All versions < V14.2.0.5; All versions < V222.0 Update 13; All versions < V223.0 Update 4; All versions < V13.2.0.15; All versions < V13.3.0.11; All versions < V14.1.0.11","affected_versions_present":true,"cve_id":"CVE-2023-28830","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-28830","fixed":"Update to V13.2.0.15 or later version","last_modified":"2024-10-23T19:49:54.534Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-131450.html","primary_source":"","published":"2023-08-08T09:20:17.760Z"},{"affected":"All versions < V14.2.0.3; All versions < V13.2.0.13; All versions < V13.3.0.10; All versions < V14.0.0.6; All versions < V14.1.0.8","affected_versions_present":true,"cve_id":"CVE-2023-33124","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-33124","fixed":"Update to V13.2.0.13 or later version","last_modified":"2025-01-03T01:37:31.531Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-538795.html","primary_source":"","published":"2023-06-13T08:17:17.687Z"},{"affected":"All versions < V14.2.0.3; All versions < V13.2.0.13; All versions < V13.3.0.10; All versions < V14.0.0.6; All versions < V14.1.0.8","affected_versions_present":true,"cve_id":"CVE-2023-33123","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-33123","fixed":"Update to V13.2.0.13 or later version","last_modified":"2025-01-03T01:38:42.204Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-538795.html","primary_source":"","published":"2023-06-13T08:17:16.585Z"},{"affected":"All versions < V14.2.0.3; All versions < V13.2.0.13; All versions < V13.3.0.10; All versions < V14.0.0.6; All versions < V14.1.0.8","affected_versions_present":true,"cve_id":"CVE-2023-33122","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-33122","fixed":"Update to V13.2.0.13 or later version","last_modified":"2025-01-03T01:40:43.732Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-538795.html","primary_source":"","published":"2023-06-13T08:17:15.483Z"},{"affected":"All versions < V14.2.0.3; All versions < V13.2.0.13; All versions < V13.3.0.10; All versions < V14.0.0.6; All versions < V14.1.0.8","affected_versions_present":true,"cve_id":"CVE-2023-33121","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-33121","fixed":"Update to V13.2.0.13 or later version","last_modified":"2025-01-03T01:42:09.311Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-538795.html","primary_source":"","published":"2023-06-13T08:17:14.419Z"},{"affected":"< 14.2.0.2; 13.2 < 13.2.0.13; 13.3 < 13.3.0.9; 14.0 < 14.0.0.5; 14.1 < 14.1.0.7; 14.2 < 14.2.0.2; \u2264 v18.0.4PlusP1e","affected_versions_present":true,"cve_id":"CVE-2023-1709","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-1709","fixed":"Update to V13.2.0.13 or later version","last_modified":"2025-01-06T19:59:28.270Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-629917.html","primary_source":"","published":"2023-06-07T20:36:05.055Z"},{"affected":"< 14.1.0.5; < 13.3.0.8; < 14.0.0.4","affected_versions_present":true,"cve_id":"CVE-2022-3161","cve_url":"https://cve.blacktree.nl/cve/CVE-2022-3161","fixed":"Update to V14.1.0.5 or later version","last_modified":"2025-01-16T22:01:39.070Z","patch_url":"https://cert-portal.siemens.com/productcert/pdf/ssa-360681.pdf","primary_source":"","published":"2023-01-13T00:17:06.310Z"},{"affected":"< 14.1.0.5; < 13.3.0.8; < 14.0.0.4","affected_versions_present":true,"cve_id":"CVE-2022-3160","cve_url":"https://cve.blacktree.nl/cve/CVE-2022-3160","fixed":"Update to V14.1.0.5 or later version","last_modified":"2025-01-16T22:01:46.182Z","patch_url":"https://cert-portal.siemens.com/productcert/pdf/ssa-360681.pdf","primary_source":"","published":"2023-01-13T00:16:30.069Z"},{"affected":"< 14.1.0.5; < 13.3.0.8; < 14.0.0.4","affected_versions_present":true,"cve_id":"CVE-2022-3159","cve_url":"https://cve.blacktree.nl/cve/CVE-2022-3159","fixed":"Update to V14.1.0.5 or later version","last_modified":"2025-01-16T22:01:53.147Z","patch_url":"https://cert-portal.siemens.com/productcert/pdf/ssa-360681.pdf","primary_source":"","published":"2023-01-13T00:15:15.775Z"},{"affected":"All versions < V14.1.0.6; All versions < V13.2.0.12; All versions < V13.3.0.9; All versions < V13.3.0.8; All versions < V14.0.0.5; All versions < V14.0.0.4","affected_versions_present":true,"cve_id":"CVE-2022-45484","cve_url":"https://cve.blacktree.nl/cve/CVE-2022-45484","fixed":"Update to V13.3.0.9 or later version","last_modified":"2025-04-21T13:43:31.045Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-700053.html","primary_source":"","published":"2022-12-13T00:00:00.000Z"},{"affected":"All versions < V14.1.0.6; All versions < V13.2.0.12; All versions < V13.3.0.8; All versions < V14.0.0.4","affected_versions_present":true,"cve_id":"CVE-2022-41288","cve_url":"https://cve.blacktree.nl/cve/CVE-2022-41288","fixed":"Update to V14.1.0.6 or later version","last_modified":"2025-04-21T13:44:05.544Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-700053.html","primary_source":"","published":"2022-12-13T00:00:00.000Z"},{"affected":"All versions < V14.1.0.6; All versions < V13.2.0.12; All versions < V13.3.0.8; All versions < V14.0.0.4","affected_versions_present":true,"cve_id":"CVE-2022-41287","cve_url":"https://cve.blacktree.nl/cve/CVE-2022-41287","fixed":"Update to V14.1.0.6 or later version","last_modified":"2024-08-03T12:42:44.640Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-700053.html","primary_source":"","published":"2022-12-13T00:00:00.000Z"},{"affected":"All versions < V14.1.0.6; All versions < V13.2.0.12; All versions < V13.3.0.8; All versions < V14.0.0.4","affected_versions_present":true,"cve_id":"CVE-2022-41286","cve_url":"https://cve.blacktree.nl/cve/CVE-2022-41286","fixed":"Update to V14.1.0.6 or later version","last_modified":"2025-04-21T13:44:15.855Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-700053.html","primary_source":"","published":"2022-12-13T00:00:00.000Z"},{"affected":"All versions < V14.1.0.6; All versions < V13.2.0.12; All versions < V13.3.0.8; All versions < V14.0.0.4","affected_versions_present":true,"cve_id":"CVE-2022-41285","cve_url":"https://cve.blacktree.nl/cve/CVE-2022-41285","fixed":"Update to V14.1.0.6 or later version","last_modified":"2025-04-21T13:44:23.773Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-700053.html","primary_source":"","published":"2022-12-13T00:00:00.000Z"},{"affected":"All versions < V14.1.0.6; All versions < V13.2.0.12; All versions < V13.3.0.8; All versions < V14.0.0.4","affected_versions_present":true,"cve_id":"CVE-2022-41284","cve_url":"https://cve.blacktree.nl/cve/CVE-2022-41284","fixed":"Update to V14.1.0.6 or later version","last_modified":"2025-04-21T13:44:31.841Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-700053.html","primary_source":"","published":"2022-12-13T00:00:00.000Z"},{"affected":"All versions < V14.1.0.6; All versions < V13.2.0.12; All versions < V13.3.0.8; All versions < V14.0.0.4","affected_versions_present":true,"cve_id":"CVE-2022-41283","cve_url":"https://cve.blacktree.nl/cve/CVE-2022-41283","fixed":"Update to V14.1.0.6 or later version","last_modified":"2025-04-21T13:44:43.158Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-700053.html","primary_source":"","published":"2022-12-13T00:00:00.000Z"},{"affected":"All versions < V14.1.0.6; All versions < V13.2.0.12; All versions < V13.3.0.8; All versions < V14.0.0.4","affected_versions_present":true,"cve_id":"CVE-2022-41282","cve_url":"https://cve.blacktree.nl/cve/CVE-2022-41282","fixed":"Update to V14.1.0.6 or later version","last_modified":"2025-04-21T13:44:50.227Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-700053.html","primary_source":"","published":"2022-12-13T00:00:00.000Z"},{"affected":"All versions < V14.1.0.6; All versions < V13.2.0.12; All versions < V13.3.0.8; All versions < V14.0.0.4","affected_versions_present":true,"cve_id":"CVE-2022-41281","cve_url":"https://cve.blacktree.nl/cve/CVE-2022-41281","fixed":"Update to V14.1.0.6 or later version","last_modified":"2025-04-21T13:44:58.713Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-700053.html","primary_source":"","published":"2022-12-13T00:00:00.000Z"},{"affected":"All versions < V14.1.0.6; All versions < V13.2.0.12; All versions < V13.3.0.8; All versions < V14.0.0.4","affected_versions_present":true,"cve_id":"CVE-2022-41280","cve_url":"https://cve.blacktree.nl/cve/CVE-2022-41280","fixed":"Update to V14.1.0.6 or later version","last_modified":"2025-04-21T13:45:08.185Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-700053.html","primary_source":"","published":"2022-12-13T00:00:00.000Z"},{"affected":"All versions < V14.1.0.6; All versions < V13.2.0.12; All versions < V13.3.0.8; All versions < V14.0.0.4","affected_versions_present":true,"cve_id":"CVE-2022-41279","cve_url":"https://cve.blacktree.nl/cve/CVE-2022-41279","fixed":"Update to V14.1.0.6 or later version","last_modified":"2025-04-21T13:45:15.469Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-700053.html","primary_source":"","published":"2022-12-13T00:00:00.000Z"},{"affected":"All versions < V14.1.0.6; All versions < V13.2.0.12; All versions < V13.3.0.8; All versions < V14.0.0.4","affected_versions_present":true,"cve_id":"CVE-2022-41278","cve_url":"https://cve.blacktree.nl/cve/CVE-2022-41278","fixed":"Update to V14.1.0.6 or later version","last_modified":"2024-08-03T12:42:45.639Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-700053.html","primary_source":"","published":"2022-12-13T00:00:00.000Z"},{"affected":"All versions < V14.1.0.4; All versions < V13.2.0.12; All versions < V13.3.0.7; All versions < V14.0.0.3; All versions < V14.1.0.4","affected_versions_present":true,"cve_id":"CVE-2022-41664","cve_url":"https://cve.blacktree.nl/cve/CVE-2022-41664","fixed":"Update to V13.2.0.12 or later version","last_modified":"2025-04-21T13:46:34.995Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-120378.html","primary_source":"","published":"2022-11-08T00:00:00.000Z"},{"affected":"All versions < V14.1.0.4; All versions < V13.2.0.12; All versions < V13.3.0.7; All versions < V14.0.0.3; All versions < V14.1.0.4","affected_versions_present":true,"cve_id":"CVE-2022-41663","cve_url":"https://cve.blacktree.nl/cve/CVE-2022-41663","fixed":"Update to V13.2.0.12 or later version","last_modified":"2025-04-21T13:46:42.304Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-120378.html","primary_source":"","published":"2022-11-08T00:00:00.000Z"},{"affected":"All versions < V14.1.0.4; All versions < V13.2.0.12; All versions < V13.3.0.7; All versions < V14.0.0.3; All versions < V14.1.0.4","affected_versions_present":true,"cve_id":"CVE-2022-41662","cve_url":"https://cve.blacktree.nl/cve/CVE-2022-41662","fixed":"Update to V13.2.0.12 or later version","last_modified":"2025-04-21T13:46:50.092Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-120378.html","primary_source":"","published":"2022-11-08T00:00:00.000Z"},{"affected":"All versions < V14.1.0.4; All versions < V13.2.0.12; All versions < V13.3.0.7; All versions < V14.0.0.3; All versions < V14.1.0.4","affected_versions_present":true,"cve_id":"CVE-2022-41661","cve_url":"https://cve.blacktree.nl/cve/CVE-2022-41661","fixed":"Update to V13.2.0.12 or later version","last_modified":"2025-04-21T13:46:57.615Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-120378.html","primary_source":"","published":"2022-11-08T00:00:00.000Z"},{"affected":"All versions < V14.1.0.4; All versions < V13.2.0.12; All versions < V13.3.0.7; All versions < V14.0.0.3; All versions < V14.1.0.4","affected_versions_present":true,"cve_id":"CVE-2022-41660","cve_url":"https://cve.blacktree.nl/cve/CVE-2022-41660","fixed":"Update to V13.2.0.12 or later version","last_modified":"2025-04-21T13:47:05.532Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-120378.html","primary_source":"","published":"2022-11-08T00:00:00.000Z"}],"source_generated_at":"2026-10-09T06:17:25.511Z","vendor":"Siemens"}}