{"api_version":"v1","generated_at":"2026-10-10T00:35:00+00:00","product":{"cve_count":2,"evidence_gap_note":"This identity is present in BlackTree CVE records, but no product-specific publisher support or retirement history is currently registered in Lifecycle.","id":"security:cve-schneider-electric-ecostruxure-process-expert-ac380e583668","lifecycle_state":"evidence_gap","linked_lifecycle_url":null,"name":"EcoStruxure Process Expert","next_cursor":null,"observations":[{"affected":"Versions 2020R2; Versions 2021 & 2023 (prior to v4.8.0.5715); Versions 2021 & 2023","affected_versions_present":true,"cve_id":"CVE-2025-0327","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-0327","fixed":"Version v4.8.0.5715 of EcoStruxure\u2122 Process Expert 2023 Software Package includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/65406-ecostruxure-process\u0002expert/#software-and-firmware Uninstall Previous Version 2023 (v4.8.0.5115) before installing Version 2023 (v4.8.0.5715). Version string could be found on engineering server console.","last_modified":"2025-02-13T14:56:12.017Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-042-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-042-03.pdf","primary_source":"","published":"2025-02-13T06:20:26.852Z"},{"affected":"V2021 and prior; V15.0 SP1 and prior","affected_versions_present":true,"cve_id":"CVE-2022-24323","cve_url":"https://cve.blacktree.nl/cve/CVE-2022-24323","fixed":"Version 15.1 of EcoStruxure\u2122 Control Expert includes a fix for these vulnerabilities and is available for download here: https://www.se.com/ww/en/download/document/EcoStruxureControlExpert_V15.1/ Customers using Unity Pro should strongly consider migrating to EcoStruxure\u2122 Control Expert. If customers choose not to apply the remediation provided above, they should immediately apply the following mitigations to reduce the risk of exploit: To mitigate the risks associated to Modbus weaknesses, users should immediately: \u2022 Setup network segmentation and implement a firewall to block all unauthorized access to port 502/TCP","last_modified":"2024-08-03T04:07:02.566Z","patch_url":"https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-067-01_EcoStruxure_Control_Expert_and_EcoStruxure_Process_Expert_Security_Notification_V2.0.pdf","primary_source":"","published":"2022-03-09T23:05:14.000Z"}],"source_generated_at":"2026-10-09T06:17:25.511Z","vendor":"Schneider Electric"}}