{"api_version":"v1","generated_at":"2026-10-10T04:35:00+00:00","product":{"cve_count":2,"evidence_gap_note":"This identity is present in BlackTree CVE records, but no product-specific publisher support or retirement history is currently registered in Lifecycle.","id":"security:cve-schneider-electric-ecostruxure-it-gateway-636e708a49a5","lifecycle_state":"evidence_gap","linked_lifecycle_url":null,"name":"EcoStruxure IT Gateway","next_cursor":null,"observations":[{"affected":"Version 1.21.0.6; Version 1.22.0.3; Version 1.22.1.5; Version 1.23.0.4","affected_versions_present":true,"cve_id":"CVE-2024-10575","cve_url":"https://cve.blacktree.nl/cve/CVE-2024-10575","fixed":"Version 1.23.1.10 of EcoStruxure\u2122 IT Gateway includes a fix for this vulnerability and is available for download here: \u2022 https://community.se.com/t5/What-s-new-in\u0002EcoStruxure-IT/Download-the-EcoStruxure-IT\u0002Gateway/ta-p/455022 \u2022 Instructions provided in the link above. \u2022 We encourage customers to enable automatic updates to receive updates promptly. \u2022 Customers who have enabled automatic updates do not need to take any further action. Prior versions are not impacted by this vulnerability.","last_modified":"2024-11-13T15:14:17.114Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-317-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-317-04.pdf","primary_source":"","published":"2024-11-13T04:35:44.556Z"},{"affected":"1.20.x and prior","affected_versions_present":true,"cve_id":"CVE-2024-0865","cve_url":"https://cve.blacktree.nl/cve/CVE-2024-0865","fixed":"Version 1.21 of EcoStruxure IT Gateway includes a fix for these vulnerabilities and is available for download here: \u2022 If you have enabled auto updates in EcoStruxure IT, then the update will be automatically applied. \u2022 If you would like to manually update, follow the instructions here to upgrade the gateway software to the latest version: https://community.se.com/t5/Gateway-software-installationand/Updating-EcoStruxure-IT-Gateway-to-the-latestversion/ta-p/447049. For further information, see System Requirements The upgrade process will perform a full remediation. After performing an upgrade to version 1.21.x or later, there are no additional steps necessary. Verify the version of EcoStruxure IT Gateway software is v1.21 or later.","last_modified":"2024-08-01T18:18:18.824Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-044-03.pdf","primary_source":"","published":"2024-06-12T17:23:00.908Z"}],"source_generated_at":"2026-10-09T06:17:25.511Z","vendor":"Schneider Electric"}}