{"api_version":"v1","generated_at":"2026-10-10T09:20:00+00:00","product":{"cve_count":2,"evidence_gap_note":"This identity is present in BlackTree CVE records, but no product-specific publisher support or retirement history is currently registered in Lifecycle.","id":"security:cve-schneider-electric-ecostruxure-geo-scada-expert-2019-2021-formerly-known-as-clearscada-dabe9328dcd5","lifecycle_state":"evidence_gap","linked_lifecycle_url":null,"name":"EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA)","next_cursor":null,"observations":[{"affected":"All < October 2022","affected_versions_present":true,"cve_id":"CVE-2023-22611","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-22611","fixed":"The October 2022 Updates of EcoStruxure Geo SCADA Expert include fixes for these vulnerabilities and are available for download here: https://community.se.com/t5/Geo-SCADA-Knowledge-Base/Geo-SCADA-Expert-Downloads/ba-p/279115 Installation of new server software will require a system restart or changeover of redundant servers. Consult the Release Notes and Exchange Knowledge Base (Resource Center) for advice on the procedure: https://community.exchange.se.com/t5/Geo-SCADA-Knowledge-Base/Resource-Center-Home/ba-p/279133 The documentation also states how to verify the installed version.","last_modified":"2025-02-05T20:06:52.179Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf","primary_source":"","published":"2023-01-31T00:00:00.000Z"},{"affected":"All < October 2022","affected_versions_present":true,"cve_id":"CVE-2023-22610","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-22610","fixed":"The October 2022 Updates of EcoStruxure Geo SCADA Expert include fixes for these vulnerabilities and are available for download here: https://community.se.com/t5/Geo-SCADA-Knowledge-Base/Geo-SCADA-Expert-Downloads/ba-p/279115 Installation of new server software will require a system restart or changeover of redundant servers. Consult the Release Notes and Exchange Knowledge Base (Resource Center) for advice on the procedure: https://community.exchange.se.com/t5/Geo-SCADA-Knowledge-Base/Resource-Center-Home/ba-p/279133 The documentation also states how to verify the installed version.","last_modified":"2025-02-05T20:06:58.944Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf","primary_source":"","published":"2023-01-31T00:00:00.000Z"}],"source_generated_at":"2026-10-10T06:21:41.304Z","vendor":"Schneider Electric"}}