{"api_version":"v1","generated_at":"2026-10-10T09:20:00+00:00","product":{"cve_count":8,"evidence_gap_note":"This identity is present in BlackTree CVE records, but no product-specific publisher support or retirement history is currently registered in Lifecycle.","id":"security:cve-rockwell-automation-1756-enbt-1756-eweb-1768-enbt-1768-eweb-communication-modules-2dc6301bd992","lifecycle_state":"evidence_gap","linked_lifecycle_url":null,"name":"1756-ENBT, 1756-EWEB, 1768-ENBT, 1768-EWEB communication modules","next_cursor":null,"observations":[{"affected":"1756-ENBT, 1756-EWEB, 1768-ENBT, 1768-EWEB communication modules: All; CompactLogix L32E and L35E controllers: All; 1788-ENBT FLEXLogix adapter: All; 1794-AENTR FLEX I/O EtherNet/IP adapter: All; ControlLogix, CompactLogix, GuardLogix, and SoftLogix: \u2264 18; CompactLogix and SoftLogix controllers: \u2264 19; ControlLogix and GuardLogix controllers: \u2264 20; MicroLogix: 1100, 1400","affected_versions_present":true,"cve_id":"CVE-2012-6442","cve_url":"https://cve.blacktree.nl/cve/CVE-2012-6442","fixed":"According to Rockwell, any of the above products that become affected by a vulnerability can be reset by rebooting or power cycling the affected product. After the reboot, the affected product may require some reconfiguration.; To mitigate the vulnerabilities, Rockwell has developed and released security patches on July 18, 2012, to address each of the issues. To download and install the patches please refer to Rockwell\u2019s Advisories at:; https://rockwellautomation.custhelp.com/app/answers/detail/a_id/470154; https://rockwellautomation.custhelp.com/app/answers/detail/aid/470155; https://rockwellautomation.custhelp.com/app/answers/detail/aid/470156; For more information on security with Rockwell Automation products, please refer to Rockwell\u2019s Security Advisory Index http://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102 .","last_modified":"2026-06-03T13:33:28.245Z","patch_url":"https://www.cisa.gov/news-events/ics-advisories/icsa-13-011-03","primary_source":"","published":"2013-01-24T21:00:00.000Z"},{"affected":"1756-ENBT, 1756-EWEB, 1768-ENBT, 1768-EWEB communication modules: All; CompactLogix L32E and L35E controllers: All; 1788-ENBT FLEXLogix adapter: All; 1794-AENTR FLEX I/O EtherNet/IP adapter: All; ControlLogix, CompactLogix, GuardLogix, and SoftLogix: \u2264 18; CompactLogix and SoftLogix controllers: \u2264 19; ControlLogix and GuardLogix controllers: \u2264 20; MicroLogix: 1100, 1400","affected_versions_present":true,"cve_id":"CVE-2012-6441","cve_url":"https://cve.blacktree.nl/cve/CVE-2012-6441","fixed":"According to Rockwell, any of the above products that become affected by a vulnerability can be reset by rebooting or power cycling the affected product. After the reboot, the affected product may require some reconfiguration.; To mitigate the vulnerabilities, Rockwell has developed and released security patches on July 18, 2012, to address each of the issues. To download and install the patches please refer to Rockwell\u2019s Advisories at:; https://rockwellautomation.custhelp.com/app/answers/detail/a_id/470154; https://rockwellautomation.custhelp.com/app/answers/detail/aid/470155; https://rockwellautomation.custhelp.com/app/answers/detail/aid/470156; For more information on security with Rockwell Automation products, please refer to Rockwell\u2019s Security Advisory Index http://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102 .","last_modified":"2025-06-30T21:43:45.657Z","patch_url":"https://www.cisa.gov/news-events/ics-advisories/icsa-13-011-03","primary_source":"","published":"2013-01-24T21:00:00.000Z"},{"affected":"1756-ENBT, 1756-EWEB, 1768-ENBT, 1768-EWEB communication modules: All; CompactLogix L32E and L35E controllers: All; 1788-ENBT FLEXLogix adapter: All; 1794-AENTR FLEX I/O EtherNet/IP adapter: All; ControlLogix, CompactLogix, GuardLogix, and SoftLogix: \u2264 18; CompactLogix and SoftLogix controllers: \u2264 19; ControlLogix and GuardLogix controllers: \u2264 20; MicroLogix: 1100, 1400","affected_versions_present":true,"cve_id":"CVE-2012-6440","cve_url":"https://cve.blacktree.nl/cve/CVE-2012-6440","fixed":"According to Rockwell, any of the above products that become affected by a vulnerability can be reset by rebooting or power cycling the affected product. After the reboot, the affected product may require some reconfiguration.; To mitigate the vulnerabilities, Rockwell has developed and released security patches on July 18, 2012, to address each of the issues. To download and install the patches please refer to Rockwell\u2019s Advisories at:; https://rockwellautomation.custhelp.com/app/answers/detail/a_id/470154; https://rockwellautomation.custhelp.com/app/answers/detail/aid/470155; https://rockwellautomation.custhelp.com/app/answers/detail/aid/470156; For more information on security with Rockwell Automation products, please refer to Rockwell\u2019s Security Advisory Index http://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102 .","last_modified":"2026-06-03T13:36:26.519Z","patch_url":"https://www.cisa.gov/news-events/ics-advisories/icsa-13-011-03","primary_source":"","published":"2013-01-24T21:00:00.000Z"},{"affected":"1756-ENBT, 1756-EWEB, 1768-ENBT, 1768-EWEB communication modules: All; CompactLogix L32E and L35E controllers: All; 1788-ENBT FLEXLogix adapter: All; 1794-AENTR FLEX I/O EtherNet/IP adapter: All; ControlLogix, CompactLogix, GuardLogix, and SoftLogix: \u2264 18; CompactLogix and SoftLogix controllers: \u2264 19; ControlLogix and GuardLogix controllers: \u2264 20; MicroLogix: 1100, 1400","affected_versions_present":true,"cve_id":"CVE-2012-6439","cve_url":"https://cve.blacktree.nl/cve/CVE-2012-6439","fixed":"According to Rockwell, any of the above products that become affected by a vulnerability can be reset by rebooting or power cycling the affected product. After the reboot, the affected product may require some reconfiguration.; To mitigate the vulnerabilities, Rockwell has developed and released security patches on July 18, 2012, to address each of the issues. To download and install the patches please refer to Rockwell\u2019s Advisories at:; https://rockwellautomation.custhelp.com/app/answers/detail/a_id/470154; https://rockwellautomation.custhelp.com/app/answers/detail/aid/470155; https://rockwellautomation.custhelp.com/app/answers/detail/aid/470156; For more information on security with Rockwell Automation products, please refer to Rockwell\u2019s Security Advisory Index http://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102 .","last_modified":"2025-06-30T21:33:10.902Z","patch_url":"http://www.us-cert.gov/control_systems/pdf/ICSA-13-011-03.pdf","primary_source":"","published":"2013-01-24T21:00:00.000Z"},{"affected":"1756-ENBT, 1756-EWEB, 1768-ENBT, 1768-EWEB communication modules: All; CompactLogix L32E and L35E controllers: All; 1788-ENBT FLEXLogix adapter: All; 1794-AENTR FLEX I/O EtherNet/IP adapter: All; ControlLogix, CompactLogix, GuardLogix, and SoftLogix: \u2264 18; CompactLogix and SoftLogix controllers: \u2264 19; ControlLogix and GuardLogix controllers: \u2264 20; MicroLogix: 1100, 1400","affected_versions_present":true,"cve_id":"CVE-2012-6438","cve_url":"https://cve.blacktree.nl/cve/CVE-2012-6438","fixed":"According to Rockwell, any of the above products that become affected by a vulnerability can be reset by rebooting or power cycling the affected product. After the reboot, the affected product may require some reconfiguration.; To mitigate the vulnerabilities, Rockwell has developed and released security patches on July 18, 2012, to address each of the issues. To download and install the patches please refer to Rockwell\u2019s Advisories at:; https://rockwellautomation.custhelp.com/app/answers/detail/a_id/470154; https://rockwellautomation.custhelp.com/app/answers/detail/aid/470155; https://rockwellautomation.custhelp.com/app/answers/detail/aid/470156; For more information on security with Rockwell Automation products, please refer to Rockwell\u2019s Security Advisory Index http://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102 .","last_modified":"2026-06-03T13:38:13.313Z","patch_url":"https://www.cisa.gov/news-events/ics-advisories/icsa-13-011-03","primary_source":"","published":"2013-01-24T21:00:00.000Z"},{"affected":"1756-ENBT, 1756-EWEB, 1768-ENBT, 1768-EWEB communication modules: All; CompactLogix L32E and L35E controllers: All; 1788-ENBT FLEXLogix adapter: All; 1794-AENTR FLEX I/O EtherNet/IP adapter: All; ControlLogix, CompactLogix, GuardLogix, and SoftLogix: \u2264 18; CompactLogix and SoftLogix controllers: \u2264 19; ControlLogix and GuardLogix controllers: \u2264 20; MicroLogix: 1100, 1400","affected_versions_present":true,"cve_id":"CVE-2012-6437","cve_url":"https://cve.blacktree.nl/cve/CVE-2012-6437","fixed":"According to Rockwell, any of the above products that become affected by a vulnerability can be reset by rebooting or power cycling the affected product. After the reboot, the affected product may require some reconfiguration.; To mitigate the vulnerabilities, Rockwell has developed and released security patches on July 18, 2012, to address each of the issues. To download and install the patches please refer to Rockwell\u2019s Advisories at:; https://rockwellautomation.custhelp.com/app/answers/detail/a_id/470154; https://rockwellautomation.custhelp.com/app/answers/detail/aid/470155; https://rockwellautomation.custhelp.com/app/answers/detail/aid/470156; For more information on security with Rockwell Automation products, please refer to Rockwell\u2019s Security Advisory Index http://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102 .","last_modified":"2026-06-03T13:39:31.275Z","patch_url":"https://www.cisa.gov/news-events/ics-advisories/icsa-13-011-03","primary_source":"","published":"2013-01-24T21:00:00.000Z"},{"affected":"1756-ENBT, 1756-EWEB, 1768-ENBT, 1768-EWEB communication modules: All; CompactLogix L32E and L35E controllers: All; 1788-ENBT FLEXLogix adapter: All; 1794-AENTR FLEX I/O EtherNet/IP adapter: All; ControlLogix, CompactLogix, GuardLogix, and SoftLogix: \u2264 18; CompactLogix and SoftLogix controllers: \u2264 19; ControlLogix and GuardLogix controllers: \u2264 20; MicroLogix: 1100, 1400","affected_versions_present":true,"cve_id":"CVE-2012-6436","cve_url":"https://cve.blacktree.nl/cve/CVE-2012-6436","fixed":"According to Rockwell, any of the above products that become affected by a vulnerability can be reset by rebooting or power cycling the affected product. After the reboot, the affected product may require some reconfiguration.; To mitigate the vulnerabilities, Rockwell has developed and released security patches on July 18, 2012, to address each of the issues. To download and install the patches please refer to Rockwell\u2019s Advisories at:; https://rockwellautomation.custhelp.com/app/answers/detail/a_id/470154; https://rockwellautomation.custhelp.com/app/answers/detail/aid/470155; https://rockwellautomation.custhelp.com/app/answers/detail/aid/470156; For more information on security with Rockwell Automation products, please refer to Rockwell\u2019s Security Advisory Index http://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102 .","last_modified":"2026-06-03T13:40:40.645Z","patch_url":"https://www.cisa.gov/news-events/ics-advisories/icsa-13-011-03","primary_source":"","published":"2013-01-24T21:00:00.000Z"},{"affected":"1756-ENBT, 1756-EWEB, 1768-ENBT, 1768-EWEB communication modules: All; CompactLogix L32E and L35E controllers: All; 1788-ENBT FLEXLogix adapter: All; 1794-AENTR FLEX I/O EtherNet/IP adapter: All; ControlLogix, CompactLogix, GuardLogix, and SoftLogix: \u2264 18; CompactLogix and SoftLogix controllers: \u2264 19; ControlLogix and GuardLogix controllers: \u2264 20; MicroLogix: 1100, 1400","affected_versions_present":true,"cve_id":"CVE-2012-6435","cve_url":"https://cve.blacktree.nl/cve/CVE-2012-6435","fixed":"According to Rockwell, any of the above products that become affected by a vulnerability can be reset by rebooting or power cycling the affected product. After the reboot, the affected product may require some reconfiguration.; To mitigate the vulnerabilities, Rockwell has developed and released security patches on July 18, 2012, to address each of the issues. To download and install the patches please refer to Rockwell\u2019s Advisories at:; https://rockwellautomation.custhelp.com/app/answers/detail/a_id/470154; https://rockwellautomation.custhelp.com/app/answers/detail/aid/470155; https://rockwellautomation.custhelp.com/app/answers/detail/aid/470156; For more information on security with Rockwell Automation products, please refer to Rockwell\u2019s Security Advisory Index http://rockwellautomation.custhelp.com/app/answers/detail/a_id/54102 .","last_modified":"2026-06-03T13:41:49.296Z","patch_url":"https://www.cisa.gov/news-events/ics-advisories/icsa-13-011-03","primary_source":"","published":"2013-01-24T21:00:00.000Z"}],"source_generated_at":"2026-10-10T06:21:41.304Z","vendor":"Rockwell Automation"}}