{"api_version":"v1","generated_at":"2026-10-09T16:30:00+00:00","product":{"cve_count":1,"evidence_gap_note":"This identity is present in BlackTree CVE records, but no product-specific publisher support or retirement history is currently registered in Lifecycle.","id":"security:cve-publisher-not-identified-somachine-basic-all-versions-ecostruxure-machine-expert-basic-all-versions-modicon-m1-515ff8c9fdff","lifecycle_state":"evidence_gap","linked_lifecycle_url":null,"name":"SoMachine Basic (all versions)EcoStruxure Machine Expert \u2013 Basic (all versions)Modicon M100 Logic Controller (all versions)Modicon M200 Logic Controller (all versions)Modicon M221 Logic Controller (all versions)","next_cursor":null,"observations":[{"affected":"SoMachine Basic (all versions)EcoStruxure Machine Expert \u2013 Basic (all versions)Modicon M100 Logic Controller (all versions)Modicon M200 Logic Controller (all versions)Modicon M221 Logic Controller (all versions)","affected_versions_present":true,"cve_id":"CVE-2020-7489","cve_url":"https://cve.blacktree.nl/cve/CVE-2020-7489","fixed":"The following workarounds and mitigations can be applied by customers to reduce the risk. All steps are required. STEP 1: Update software and firmware. \u2022 On the engineering workstation, update to EcoStruxure Machine Expert - Basic V1.0 SP2 or above: https://www.se.com/fr/fr/product-range-download/2226- ecostruxure%E2%84%A2-machine-expert/#/software-firmware-tab \u2022 On Modicon M100/M200/M221 Logic controllers, update to latest firmware version. STEP 2: Update projects in EcoStruxure Machine Expert \u2013 Basic. \u2022 Upgrade the functional level of the application to version 10.2 Activate the application protection for both read and write in the project properties STEP 3: Transfer applications. \u2022 Transfer applications to Modicon M100/M200/M221 logic controllers. EcoStruxure Machine Expert \u2013 Basic will perform integrity check when transferring the application and will display a warning pop-up to the user if the application has been altered during transfer.","last_modified":"2026-05-28T20:30:39.144Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2020-105-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2020-105-01_Modicon%20M100_M200_M221_and_EcoStruxure%E2%84%A2_Machine%20Expert_Basic_Security_Notification.pdf","primary_source":"","published":"2020-04-22T18:15:57.000Z"}],"source_generated_at":"2026-10-09T06:17:25.511Z","vendor":"Publisher not identified"}}
