{"api_version":"v1","generated_at":"2026-10-10T08:10:00+00:00","product":{"cve_count":5,"evidence_gap_note":"This identity is present in BlackTree CVE records, but no product-specific publisher support or retirement history is currently registered in Lifecycle.","id":"security:cve-publisher-not-identified-plc-simulator-on-ecostruxurea-control-expert-now-unity-pro-all-versions-5a2a2794ad3a","lifecycle_state":"evidence_gap","linked_lifecycle_url":null,"name":"PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions)","next_cursor":null,"observations":[{"affected":"PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions)","affected_versions_present":true,"cve_id":"CVE-2020-7559","cve_url":"https://cve.blacktree.nl/cve/CVE-2020-7559","fixed":"EcoStruxure\u2122 Control Expert Version 15.0 SP1 product includes a fix for the vulnerability CVE-2020-7559 and is available for download here: https://www.se.com/ww/en/download/document/EcoStruxureControlExpert_15SP1 Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch. If customers choose not to apply the remediation provided above, they should immediately follow the recommendations in the Mitigation section below to reduce the risk of exploit.","last_modified":"2024-08-04T09:33:19.465Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2020-315-07&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2020-315-07_PLC_Simulator_on_EcoStruxure%E2%84%A2_Control_Expert_and_Process_Expert_Security_Notification.pdf","primary_source":"","published":"2020-11-19T21:04:25.000Z"},{"affected":"PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions)","affected_versions_present":true,"cve_id":"CVE-2020-7538","cve_url":"https://cve.blacktree.nl/cve/CVE-2020-7538","fixed":"EcoStruxure\u2122 Control Expert Version 15.0 SP1 product includes a fix for the vulnerability CVE-2020-7559 and is available for download here: https://www.se.com/ww/en/download/document/EcoStruxureControlExpert_15SP1 Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch. If customers choose not to apply the remediation provided above, they should immediately follow the recommendations in the Mitigation section below to reduce the risk of exploit.","last_modified":"2024-08-04T09:33:19.804Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2020-315-07&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2020-315-07_PLC_Simulator_on_EcoStruxure%E2%84%A2_Control_Expert_and_Process_Expert_Security_Notification.pdf","primary_source":"","published":"2020-11-19T21:04:18.000Z"},{"affected":"PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions)","affected_versions_present":true,"cve_id":"CVE-2020-28213","cve_url":"https://cve.blacktree.nl/cve/CVE-2020-28213","fixed":"EcoStruxure\u2122 Control Expert Version 15.0 SP1 product includes a fix for the vulnerability CVE-2020-7559 and is available for download here: https://www.se.com/ww/en/download/document/EcoStruxureControlExpert_15SP1 Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch. If customers choose not to apply the remediation provided above, they should immediately follow the recommendations in the Mitigation section below to reduce the risk of exploit.","last_modified":"2024-08-04T16:33:58.563Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2020-315-07&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2020-315-07_PLC_Simulator_on_EcoStruxure%E2%84%A2_Control_Expert_and_Process_Expert_Security_Notification.pdf","primary_source":"","published":"2020-11-19T21:03:54.000Z"},{"affected":"PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions)","affected_versions_present":true,"cve_id":"CVE-2020-28212","cve_url":"https://cve.blacktree.nl/cve/CVE-2020-28212","fixed":"EcoStruxure\u2122 Control Expert Version 15.0 SP1 product includes a fix for the vulnerability CVE-2020-7559 and is available for download here: https://www.se.com/ww/en/download/document/EcoStruxureControlExpert_15SP1 Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch. If customers choose not to apply the remediation provided above, they should immediately follow the recommendations in the Mitigation section below to reduce the risk of exploit.","last_modified":"2024-08-04T16:33:58.114Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2020-315-07&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2020-315-07_PLC_Simulator_on_EcoStruxure%E2%84%A2_Control_Expert_and_Process_Expert_Security_Notification.pdf","primary_source":"","published":"2020-11-19T21:03:43.000Z"},{"affected":"PLC Simulator on EcoStruxure\u00aa Control Expert (now Unity Pro) (all versions)","affected_versions_present":true,"cve_id":"CVE-2020-28211","cve_url":"https://cve.blacktree.nl/cve/CVE-2020-28211","fixed":"EcoStruxure\u2122 Control Expert Version 15.0 SP1 product includes a fix for the vulnerability CVE-2020-7559 and is available for download here: https://www.se.com/ww/en/download/document/EcoStruxureControlExpert_15SP1 Customers should use appropriate patching methodologies when applying these patches to their systems. We strongly recommend the use of back-ups and evaluating the impact of these patches in a Test and Development environment or on an offline infrastructure. Contact Schneider Electric\u2019s Customer Care Center if you need assistance removing a patch. If customers choose not to apply the remediation provided above, they should immediately follow the recommendations in the Mitigation section below to reduce the risk of exploit.","last_modified":"2024-08-04T16:33:58.139Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2020-315-07&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2020-315-07_PLC_Simulator_on_EcoStruxure%E2%84%A2_Control_Expert_and_Process_Expert_Security_Notification.pdf","primary_source":"","published":"2020-11-19T21:03:37.000Z"}],"source_generated_at":"2026-10-10T06:21:41.304Z","vendor":"Publisher not identified"}}