{"api_version":"v1","generated_at":"2026-10-08T17:30:00+00:00","product":{"cve_count":116,"evidence_gap_note":"This CVE identity is linked to an existing Lifecycle product history.","id":"security:cve-fortinet-fortios-ff51e2260dda","lifecycle_state":"covered","linked_lifecycle_url":"https://lifecycle.blacktree.nl/targets/fortios","name":"FortiOS","next_cursor":"djE6NTA","observations":[{"affected":"7.4.0 \u2264 7.4.12; 7.2.0 \u2264 7.2.13; 7.0.0 \u2264 7.0.19; 6.4.0 \u2264 6.4.16; 7.6.0 \u2264 7.6.6; 7.4.0 \u2264 7.4.14; 7.2.0 \u2264 7.2.16; 1.9.0","affected_versions_present":true,"cve_id":"CVE-2026-84392","cve_url":"https://cve.blacktree.nl/cve/CVE-2026-84392","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-09-08T17:28:27.907Z","patch_url":"","primary_source":"","published":"2026-09-08T16:42:06.190Z"},{"affected":"7.6.1 \u2264 7.6.6; 7.6.2 \u2264 7.6.6","affected_versions_present":true,"cve_id":"CVE-2026-84393","cve_url":"https://cve.blacktree.nl/cve/CVE-2026-84393","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-09-10T03:56:52.472Z","patch_url":"","primary_source":"","published":"2026-09-08T16:41:49.203Z"},{"affected":"7.6.1 \u2264 7.6.6; 1.8.0 \u2264 1.8.4; 1.7.0 \u2264 1.7.2; 1.6.0 \u2264 1.6.2; 1.5.0 \u2264 1.5.1; 1.4.0 \u2264 1.4.3; 1.3.0 \u2264 1.3.1; 1.2.0","affected_versions_present":true,"cve_id":"CVE-2026-71407","cve_url":"https://cve.blacktree.nl/cve/CVE-2026-71407","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-08-13T03:55:40.765Z","patch_url":"","primary_source":"","published":"2026-08-12T12:19:02.684Z"},{"affected":"7.6.0 \u2264 7.6.6; 7.4.0 \u2264 7.4.12; 7.2.0 \u2264 7.2.13; 7.0.0 \u2264 7.0.19; 6.4.0 \u2264 6.4.16","affected_versions_present":true,"cve_id":"CVE-2026-71408","cve_url":"https://cve.blacktree.nl/cve/CVE-2026-71408","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-08-12T13:43:25.034Z","patch_url":"https://fortiguard.fortinet.com/psirt/FG-IR-26-162","primary_source":"","published":"2026-08-12T12:19:00.441Z"},{"affected":"7.6.0 \u2264 7.6.3; 7.4.0 \u2264 7.4.8; 7.2.0 \u2264 7.2.13; 7.0.0 \u2264 7.0.19; 6.4.0 \u2264 6.4.16; 1.7.0; 1.6.0 \u2264 1.6.2; 1.5.0 \u2264 1.5.1","affected_versions_present":true,"cve_id":"CVE-2026-59840","cve_url":"https://cve.blacktree.nl/cve/CVE-2026-59840","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-08-11T12:23:48.662Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-864900.html","primary_source":"","published":"2026-07-14T15:19:51.309Z"},{"affected":"FortiOS: 7.4.0 \u2264 7.4.3, 7.2.0 \u2264 7.2.13, 7.0.0 \u2264 7.0.19","affected_versions_present":true,"cve_id":"CVE-2025-43892","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-43892","fixed":"Upgrade to FortiOS version 7.6.4 or above; Upgrade to FortiOS version 7.4.9 or above; Fortinet remediated this issue in FortiSASE version 25.4.b and hence customers do not need to perform any action.; Upgrade to FortiProxy version 7.6.6 or above; Upgrade to FortiProxy version 7.4.14 or above","last_modified":"2026-08-11T12:23:04.385Z","patch_url":"https://fortiguard.fortinet.com/psirt/#5944","primary_source":"","published":"2026-07-14T15:19:51.080Z"},{"affected":"7.6.0 \u2264 7.6.6; 7.4.0 \u2264 7.4.12; 7.2.0 \u2264 7.2.13; 7.0.0 \u2264 7.0.19; 6.4.0 \u2264 6.4.16; 7.4.0 \u2264 7.4.3; 7.2.0 \u2264 7.2.9; 7.0.0 \u2264 7.0.16","affected_versions_present":true,"cve_id":"CVE-2026-23573","cve_url":"https://cve.blacktree.nl/cve/CVE-2026-23573","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-08-11T12:23:38.148Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-127084.html","primary_source":"","published":"2026-07-14T15:19:47.183Z"},{"affected":"FortiOS: 7.6.0 \u2264 7.6.4, 7.4.0 \u2264 7.4.12, 7.2.0 \u2264 7.2.13, 7.0.0 \u2264 7.0.19, 6.4.0 \u2264 6.4.16; FortiPAM: 1.7.0, 1.6.0 \u2264 1.6.2, 1.5.0 \u2264 1.5.1, 1.4.0 \u2264 1.4.3, 1.3.0 \u2264 1.3.1, 1.2.0, 1.1.0 \u2264 1.1.2, 1.0.0 \u2264 1.0.3; FortiProxy: 7.6.0 \u2264 7.6.4, 7.4.0 \u2264 7.4.14, 7.2.0 \u2264 7.2.16, 7.0.0 \u2264 7.0.23","affected_versions_present":true,"cve_id":"CVE-2025-62675","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-62675","fixed":"Fortinet remediated this issue in FortiSASE version 25.4.b and hence customers do not need to perform any action.; Upgrade to FortiProxy version 7.6.5 or above; Upgrade to FortiOS version 8.0.0 or above; Upgrade to FortiOS version 7.6.5 or above","last_modified":"2026-08-11T12:23:16.561Z","patch_url":"https://fortiguard.fortinet.com/psirt/FG-IR-26-152","primary_source":"","published":"2026-07-14T15:15:12.695Z"},{"affected":"7.6.0 \u2264 7.6.1; 7.4.0 \u2264 7.4.6; 7.2.0 \u2264 7.2.10; 7.0.0 \u2264 7.0.16; 6.4.0 \u2264 6.4.16; 7.6.0 \u2264 7.6.3; 7.4.0 \u2264 7.4.10; 7.2.0 \u2264 7.2.14","affected_versions_present":true,"cve_id":"CVE-2025-67862","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-67862","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-08-11T12:23:18.788Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-864900.html","primary_source":"","published":"2026-06-09T14:27:50.485Z"},{"affected":"FortiOS: 7.6.0 \u2264 7.6.3, 7.4.0 \u2264 7.4.8, 7.2.0 \u2264 7.2.11, 7.0.0 \u2264 7.0.17, 6.4.0 \u2264 6.4.16, 6.2.0 \u2264 6.2.17, 6.0.0 \u2264 6.0.18","affected_versions_present":true,"cve_id":"CVE-2025-53844","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-53844","fixed":"Upgrade to FortiOS version 7.6.4 or above; Upgrade to FortiOS version 7.4.9 or above; Upgrade to FortiOS version 7.2.12 or above; Upgrade to FortiOS version 7.0.18 or above; Fortinet remediated this issue in FortiSASE version 25.3.a and hence customers do not need to perform any action.; Upgrade to FortiSwitchManager version 7.2.7 or above; Upgrade to FortiSwitchManager version 7.0.6 or above; Fortinet remediated this issue in FortiEdgeCloud version 25.3 and hence customers do not need to perform any action.","last_modified":"2026-08-11T12:23:08.810Z","patch_url":"https://fortiguard.fortinet.com/psirt/FG-IR-26-123","primary_source":"","published":"2026-05-12T16:54:10.126Z"},{"affected":"7.6.0 \u2264 7.6.4; 7.4.0 \u2264 7.4.9; 7.2.0 \u2264 7.2.13; 7.0.0 \u2264 7.0.19; 6.4.0 \u2264 6.4.16; 7.4.0 \u2264 7.4.11; 7.2.0 \u2264 7.2.16; 7.0.0 \u2264 7.0.23","affected_versions_present":true,"cve_id":"CVE-2025-61624","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-61624","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-05-12T12:08:31.410Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-975644.html","primary_source":"","published":"2026-04-14T15:39:51.445Z"},{"affected":"FortiOS: 7.6.0 \u2264 7.6.3, 7.4.0 \u2264 7.4.8, 7.2.0 \u2264 7.2.11, 7.0.0 \u2264 7.0.17, 6.4.0 \u2264 6.4.16, 6.2.9 \u2264 6.2.17","affected_versions_present":true,"cve_id":"CVE-2025-53847","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-53847","fixed":"Upgrade to FortiOS version 7.6.4 or above; Upgrade to FortiOS version 7.4.9 or above; Upgrade to FortiOS version 7.2.12 or above; Upgrade to FortiOS version 7.0.18 or above","last_modified":"2026-05-12T12:08:24.927Z","patch_url":"https://fortiguard.fortinet.com/psirt/FG-IR-26-125","primary_source":"","published":"2026-04-14T15:38:06.336Z"},{"affected":"7.6.0 \u2264 7.6.4; 7.4.0 \u2264 7.4.9; 7.2.0 \u2264 7.2.13; 7.0.0 \u2264 7.0.19","affected_versions_present":true,"cve_id":"CVE-2025-62439","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-62439","fixed":"Update Fortigate NGFW to V7.4.10 or later version with FSSO TS Agent version 5.0 build 0324 or later version. Contact customer support to receive patch and update information","last_modified":"2026-05-12T12:08:35.887Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-975644.html","primary_source":"","published":"2026-02-10T15:39:12.842Z"},{"affected":"FortiOS: 7.6.0 \u2264 7.6.1, 7.4.0 \u2264 7.4.6, 7.2.0 \u2264 7.2.13, 7.0.0 \u2264 7.0.19, 6.4.0 \u2264 6.4.16","affected_versions_present":true,"cve_id":"CVE-2025-68686","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-68686","fixed":"Upgrade to FortiOS version 7.6.2 or above; Upgrade to FortiOS version 7.4.7 or above","last_modified":"2026-07-28T03:55:36.619Z","patch_url":"https://fortiguard.fortinet.com/psirt/FG-IR-25-934","primary_source":"","published":"2026-02-10T15:39:12.777Z"},{"affected":"7.6.0 \u2264 7.6.4; 7.4.0 \u2264 7.4.9; 7.2.0 \u2264 7.2.11; 7.0.0 \u2264 7.0.19","affected_versions_present":true,"cve_id":"CVE-2025-64157","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-64157","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-05-12T12:08:37.024Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-975644.html","primary_source":"","published":"2026-02-10T15:39:12.760Z"},{"affected":"7.6.0; 7.4.0 \u2264 7.4.9; 7.2.0 \u2264 7.2.13; 7.0.0 \u2264 7.0.19; 6.4.3 \u2264 6.4.16","affected_versions_present":true,"cve_id":"CVE-2025-55018","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-55018","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-05-12T12:08:26.052Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-975644.html","primary_source":"","published":"2026-02-10T15:39:12.431Z"},{"affected":"7.6.0 \u2264 7.6.4","affected_versions_present":true,"cve_id":"CVE-2026-22153","cve_url":"https://cve.blacktree.nl/cve/CVE-2026-22153","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-02-26T15:04:11.526Z","patch_url":"","primary_source":"","published":"2026-02-10T15:39:12.214Z"},{"affected":"\u2264 7.6.6","affected_versions_present":true,"cve_id":"CVE-2026-25815","cve_url":"https://cve.blacktree.nl/cve/CVE-2026-25815","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-02-09T19:31:50.964Z","patch_url":"","primary_source":"","published":"2026-02-05T21:14:09.241Z"},{"affected":"7.4.0; 7.2.0 \u2264 7.2.13; 7.0.0 \u2264 7.0.19; 6.4.0 \u2264 6.4.16","affected_versions_present":true,"cve_id":"CVE-2025-62631","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-62631","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-05-12T09:57:29.315Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-366067.html","primary_source":"","published":"2025-12-09T17:18:47.955Z"},{"affected":"7.6.0 \u2264 7.6.3; 7.4.0 \u2264 7.4.8; 7.2.0 \u2264 7.2.12; 7.0.0 \u2264 7.0.18; 6.4.0 \u2264 6.4.16","affected_versions_present":true,"cve_id":"CVE-2025-53843","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-53843","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-08-11T12:23:07.706Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-864900.html","primary_source":"","published":"2025-11-18T17:01:28.239Z"},{"affected":"7.6.0 \u2264 7.6.3; 7.4.0 \u2264 7.4.8; 7.2.0 \u2264 7.2.12; 7.0.0 \u2264 7.0.18; 6.4.0 \u2264 6.4.16; 6.2.0 \u2264 6.2.17; 6.0.0 \u2264 6.0.18; 25.3.b","affected_versions_present":true,"cve_id":"CVE-2025-58413","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-58413","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-08-11T12:23:12.133Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-864900.html","primary_source":"","published":"2025-11-18T17:01:22.032Z"},{"affected":"7.6.0 \u2264 7.6.2; 7.4.0 \u2264 7.4.11; 7.2.0 \u2264 7.2.13; 7.0.0 \u2264 7.0.19; 6.4.0 \u2264 6.4.16; 7.6.0 \u2264 7.6.3; 7.4.0 \u2264 7.4.13; 7.2.0 \u2264 7.2.16","affected_versions_present":true,"cve_id":"CVE-2025-31514","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-31514","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-08-11T12:22:49.395Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-864900.html","primary_source":"","published":"2025-10-14T15:23:52.883Z"},{"affected":"7.6.0 \u2264 7.6.3; 7.4.0 \u2264 7.4.11; 7.2.0 \u2264 7.2.15; 7.0.1 \u2264 7.0.22","affected_versions_present":true,"cve_id":"CVE-2025-25255","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-25255","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-01-14T09:18:28.360Z","patch_url":"","primary_source":"","published":"2025-10-14T15:23:09.821Z"},{"affected":"FortiOS: 7.6.0 \u2264 7.6.2, 7.4.0 \u2264 7.4.6, 7.2.0 \u2264 7.2.10, 7.0.0 \u2264 7.0.16, 6.4.0 \u2264 6.4.16","affected_versions_present":true,"cve_id":"CVE-2025-25252","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-25252","fixed":"Upgrade to FortiOS version 7.6.3 or above; Upgrade to FortiOS version 7.4.7 or above","last_modified":"2026-09-13T03:55:21.219Z","patch_url":"https://fortiguard.fortinet.com/psirt/FG-IR-24-487","primary_source":"","published":"2025-10-14T15:23:08.121Z"},{"affected":"7.4.0 \u2264 7.4.1; 7.2.0 \u2264 7.2.11; 7.0.0 \u2264 7.0.18; 6.4.6 \u2264 6.4.16; 6.2.9 \u2264 6.2.17; 6.0.13 \u2264 6.0.18; 7.4.0 \u2264 7.4.7; 7.2.0 \u2264 7.2.15","affected_versions_present":true,"cve_id":"CVE-2023-46718","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-46718","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-02-26T17:47:33.425Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-832273.html","primary_source":"","published":"2025-10-14T15:23:02.581Z"},{"affected":"7.6.0 \u2264 7.6.2; 7.4.0 \u2264 7.4.8; 7.2.0 \u2264 7.2.13; 7.0.0 \u2264 7.0.19; 6.4.0 \u2264 6.4.16; 7.6.0 \u2264 7.6.3; 7.4.0 \u2264 7.4.14; 7.2.0 \u2264 7.2.16","affected_versions_present":true,"cve_id":"CVE-2025-47890","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-47890","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-08-11T12:23:05.493Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-864900.html","primary_source":"","published":"2025-10-14T15:22:50.356Z"},{"affected":"7.6.0; 7.4.0 \u2264 7.4.5; 7.2.5 \u2264 7.2.10; 7.0.0 \u2264 7.0.15; 6.4.0 \u2264 6.4.16","affected_versions_present":true,"cve_id":"CVE-2025-58325","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-58325","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-02-26T17:47:36.552Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-770770.html","primary_source":"","published":"2025-10-14T15:22:39.254Z"},{"affected":"7.6.0 \u2264 7.6.3; 7.4.0 \u2264 7.4.8; 7.2.0 \u2264 7.2.12; 7.0.0 \u2264 7.0.18; 6.4.0 \u2264 6.4.16","affected_versions_present":true,"cve_id":"CVE-2025-58903","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-58903","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-08-11T12:23:13.241Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-864900.html","primary_source":"","published":"2025-10-14T15:22:34.563Z"},{"affected":"7.6.0 \u2264 7.6.2; 7.4.0 \u2264 7.4.7; 7.2.0 \u2264 7.2.10; 7.0.0 \u2264 7.0.17; 6.4.0 \u2264 6.4.16; 1.5.0; 1.4.0 \u2264 1.4.2; 1.3.0 \u2264 1.3.1","affected_versions_present":true,"cve_id":"CVE-2025-25248","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-25248","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-08-11T12:22:43.770Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-864900.html","primary_source":"","published":"2025-08-12T18:59:39.985Z"},{"affected":"7.6.0 \u2264 7.6.2; 7.4.0 \u2264 7.4.7; 7.2.0 \u2264 7.2.11; 7.0.0 \u2264 7.0.17; 6.4.0 \u2264 6.4.16","affected_versions_present":true,"cve_id":"CVE-2025-53744","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-53744","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-08-11T12:23:06.601Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-864900.html","primary_source":"","published":"2025-08-12T18:59:22.011Z"},{"affected":"7.6.0 \u2264 7.6.2; 7.4.0 \u2264 7.4.7; 7.2.4 \u2264 7.2.12","affected_versions_present":true,"cve_id":"CVE-2025-24477","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-24477","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-02-10T07:25:10.256Z","patch_url":"","primary_source":"","published":"2025-07-15T08:14:41.283Z"},{"affected":"7.6.0 \u2264 7.6.1; 7.4.0 \u2264 7.4.5; 7.2.0 \u2264 7.2.10; 7.0.1 \u2264 7.0.16; 7.4.0 \u2264 7.4.8; 7.2.0 \u2264 7.2.13; 7.0.0 \u2264 7.0.20","affected_versions_present":true,"cve_id":"CVE-2024-52965","cve_url":"https://cve.blacktree.nl/cve/CVE-2024-52965","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2025-07-08T20:41:57.917Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-770770.html","primary_source":"","published":"2025-07-08T14:41:38.347Z"},{"affected":"7.6.0; 7.4.0 \u2264 7.4.7; 7.2.0 \u2264 7.2.10; 7.0.0 \u2264 7.0.17; 6.4.0 \u2264 6.4.16; 7.6.0 \u2264 7.6.1; 7.4.0 \u2264 7.4.8; 7.2.0 \u2264 7.2.14","affected_versions_present":true,"cve_id":"CVE-2024-55599","cve_url":"https://cve.blacktree.nl/cve/CVE-2024-55599","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-08-11T12:22:35.606Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-864900.html","primary_source":"","published":"2025-07-08T14:41:34.245Z"},{"affected":"7.4.0 \u2264 7.4.3; 7.2.0 \u2264 7.2.7; 7.0.0 \u2264 7.0.14; 6.4.2 \u2264 6.4.16; 7.2.0 \u2264 7.2.9; 7.0.0 \u2264 7.0.16","affected_versions_present":true,"cve_id":"CVE-2024-50568","cve_url":"https://cve.blacktree.nl/cve/CVE-2024-50568","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2025-06-10T18:49:54.977Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-698820.html","primary_source":"","published":"2025-06-10T16:36:21.786Z"},{"affected":"7.6.0; 7.4.0 \u2264 7.4.7; 7.2.0 \u2264 7.2.13; 7.0.0 \u2264 7.0.19; 6.4.0 \u2264 6.4.16; 25.1.c","affected_versions_present":true,"cve_id":"CVE-2025-25250","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-25250","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-08-11T12:22:46.018Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-864900.html","primary_source":"","published":"2025-06-10T16:36:19.264Z"},{"affected":"7.6.0 \u2264 7.6.1; 7.4.0 \u2264 7.4.7","affected_versions_present":true,"cve_id":"CVE-2025-24471","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-24471","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-08-11T12:22:42.664Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-864900.html","primary_source":"","published":"2025-06-10T16:36:18.093Z"},{"affected":"7.6.0 \u2264 7.6.1; 7.4.0 \u2264 7.4.6; 7.2.0 \u2264 7.2.10; 7.0.0 \u2264 7.0.16; 6.4.0 \u2264 6.4.15; 7.4.0 \u2264 7.4.7","affected_versions_present":true,"cve_id":"CVE-2025-22254","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-22254","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-02-26T17:50:58.674Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-770770.html","primary_source":"","published":"2025-06-10T16:36:17.127Z"},{"affected":"7.6.0; 7.4.0 \u2264 7.4.5; 7.2.0 \u2264 7.2.11; 7.0.0 \u2264 7.0.17; 6.4.0 \u2264 6.4.16","affected_versions_present":true,"cve_id":"CVE-2025-22251","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-22251","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2025-06-10T19:40:04.946Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-770770.html","primary_source":"","published":"2025-06-10T16:36:12.689Z"},{"affected":"7.6.0; 7.4.6; 7.4.0 \u2264 7.4.4; 7.2.0 \u2264 7.2.10; 7.0.0 \u2264 7.0.17; 6.4.0 \u2264 6.4.16; 1.4.0 \u2264 1.4.1; 1.3.0","affected_versions_present":true,"cve_id":"CVE-2024-50562","cve_url":"https://cve.blacktree.nl/cve/CVE-2024-50562","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-08-11T12:22:33.367Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-864900.html","primary_source":"","published":"2025-06-10T16:36:10.666Z"},{"affected":"7.2.0 \u2264 7.2.7; 7.0.0 \u2264 7.0.14; 6.4.0 \u2264 6.4.16","affected_versions_present":true,"cve_id":"CVE-2025-47294","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-47294","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2025-05-28T14:19:04.332Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-366067.html","primary_source":"","published":"2025-05-28T07:55:39.827Z"},{"affected":"7.4.0 \u2264 7.4.3; 7.2.0 \u2264 7.2.7; 7.0.0 \u2264 7.0.14; 6.4.0 \u2264 6.4.16","affected_versions_present":true,"cve_id":"CVE-2025-47295","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-47295","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2025-05-28T14:23:42.935Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-698820.html","primary_source":"","published":"2025-05-28T07:54:05.794Z"},{"affected":"7.4.0 \u2264 7.4.4; 7.2.0 \u2264 7.2.8; 7.0.0 \u2264 7.0.15; 6.4.0 \u2264 6.4.16; 6.2.0 \u2264 6.2.16; 7.0.0 \u2264 7.0.2; 6.4.0 \u2264 6.4.8; 6.0.0 \u2264 6.0.12","affected_versions_present":true,"cve_id":"CVE-2024-50565","cve_url":"https://cve.blacktree.nl/cve/CVE-2024-50565","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2025-04-08T14:22:56.685Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-770770.html","primary_source":"","published":"2025-04-08T14:03:51.519Z"},{"affected":"7.4.0 \u2264 7.4.8; 7.2.0 \u2264 7.2.12; 7.0.0 \u2264 7.0.18; 6.4.0 \u2264 6.4.16","affected_versions_present":true,"cve_id":"CVE-2024-32122","cve_url":"https://cve.blacktree.nl/cve/CVE-2024-32122","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-08-11T12:22:32.251Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-864900.html","primary_source":"","published":"2025-04-08T14:02:57.071Z"},{"affected":"6.4.0 \u2264 6.4.1; 6.2.0 \u2264 6.2.9","affected_versions_present":true,"cve_id":"CVE-2019-16151","cve_url":"https://cve.blacktree.nl/cve/CVE-2019-16151","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2025-03-21T16:22:17.554Z","patch_url":"","primary_source":"","published":"2025-03-21T16:02:01.913Z"},{"affected":"6.2.0 \u2264 6.2.1","affected_versions_present":true,"cve_id":"CVE-2019-6697","cve_url":"https://cve.blacktree.nl/cve/CVE-2019-6697","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2025-03-17T17:56:56.460Z","patch_url":"","primary_source":"","published":"2025-03-17T13:40:57.520Z"},{"affected":"6.2.1 \u2264 6.2.4; 6.0.0 \u2264 6.0.10","affected_versions_present":true,"cve_id":"CVE-2020-29010","cve_url":"https://cve.blacktree.nl/cve/CVE-2020-29010","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2025-03-17T13:32:38.996Z","patch_url":"","primary_source":"","published":"2025-03-17T13:06:16.993Z"},{"affected":"7.4.0 \u2264 7.4.4; 7.2.4 \u2264 7.2.8","affected_versions_present":true,"cve_id":"CVE-2024-35279","cve_url":"https://cve.blacktree.nl/cve/CVE-2024-35279","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-02-26T19:09:16.696Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-770770.html","primary_source":"","published":"2025-02-11T16:09:02.911Z"},{"affected":"7.6.0; 7.4.0 \u2264 7.4.4; 7.2.0 \u2264 7.2.9; 7.0.0 \u2264 7.0.15; 6.4.0 \u2264 6.4.15","affected_versions_present":true,"cve_id":"CVE-2024-40591","cve_url":"https://cve.blacktree.nl/cve/CVE-2024-40591","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2026-02-26T19:09:17.178Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-770770.html","primary_source":"","published":"2025-02-11T16:09:02.843Z"},{"affected":"7.4.0 \u2264 7.4.4; 7.2.0 \u2264 7.2.8; 7.0.0 \u2264 7.0.16; 6.4.0 \u2264 6.4.15","affected_versions_present":true,"cve_id":"CVE-2024-36504","cve_url":"https://cve.blacktree.nl/cve/CVE-2024-36504","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2025-02-18T21:38:19.515Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-770770.html","primary_source":"","published":"2025-01-14T14:09:58.824Z"},{"affected":"7.6.0; 7.4.0 \u2264 7.4.4; 7.2.0 \u2264 7.2.10; 7.0.0 \u2264 7.0.16; 6.4.0 \u2264 6.4.15","affected_versions_present":true,"cve_id":"CVE-2024-46666","cve_url":"https://cve.blacktree.nl/cve/CVE-2024-46666","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2025-02-18T21:39:30.528Z","patch_url":"https://cert-portal.siemens.com/productcert/html/ssa-770770.html","primary_source":"","published":"2025-01-14T14:09:56.935Z"}],"source_generated_at":"2026-10-08T06:18:52.353Z","vendor":"Fortinet, Inc."}}