{"api_version":"v1","generated_at":"2026-10-06T23:50:00+00:00","product":{"cve_count":21,"evidence_gap_note":"This identity is present in BlackTree CVE records, but no product-specific publisher support or retirement history is currently registered in Lifecycle.","id":"security:cve-codesys-codesys-control-for-beaglebone-sl-e21c262fbfab","lifecycle_state":"evidence_gap","linked_lifecycle_url":null,"name":"CODESYS Control for BeagleBone SL","next_cursor":null,"observations":[{"affected":"< 4.16.0.0","affected_versions_present":true,"cve_id":"CVE-2025-0694","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-0694","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2025-03-18T13:09:54.473Z","patch_url":"","primary_source":"","published":"2025-03-18T11:04:06.167Z"},{"affected":"< 4.14.0.0","affected_versions_present":true,"cve_id":"CVE-2024-8175","cve_url":"https://cve.blacktree.nl/cve/CVE-2024-8175","fixed":"The problem is corrected in AC500 V3 firmware version 3.8.0. ABB recommends that customers apply the update at earliest convenience. This firmware version is released for all AC500 V3 PLC types and available from Automation Builder 2.8.0.","last_modified":"2024-09-25T14:02:28.368Z","patch_url":"https://search.abb.com/library/Download.aspx?DocumentID=3ADR011377&LanguageCode=en&DocumentPartId=&Action=Launch","primary_source":"","published":"2024-09-25T08:04:23.196Z"},{"affected":"< 4.12.0.0","affected_versions_present":true,"cve_id":"CVE-2024-5000","cve_url":"https://cve.blacktree.nl/cve/CVE-2024-5000","fixed":"The problem is corrected in AC500 V3 firmware version 3.8.0. ABB recommends that customers apply the update at earliest convenience. This firmware version is released for all AC500 V3 PLC types and available from Automation Builder 2.8.0.","last_modified":"2024-08-01T20:55:10.389Z","patch_url":"https://search.abb.com/library/Download.aspx?DocumentID=3ADR011377&LanguageCode=en&DocumentPartId=&Action=Launch","primary_source":"","published":"2024-06-04T08:54:06.522Z"},{"affected":"< 4.11.0.0","affected_versions_present":true,"cve_id":"CVE-2023-6357","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-6357","fixed":"The problem is corrected in AC500 V3 firmware version 3.8.0. ABB recommends that customers apply the update at earliest convenience. This firmware version is released for all AC500 V3 PLC types and available from Automation Builder 2.8.0.","last_modified":"2024-08-02T08:28:21.783Z","patch_url":"https://search.abb.com/library/Download.aspx?DocumentID=3ADR011377&LanguageCode=en&DocumentPartId=&Action=Launch","primary_source":"","published":"2023-12-05T14:29:25.649Z"},{"affected":"all","affected_versions_present":true,"cve_id":"CVE-2022-4046","cve_url":"https://cve.blacktree.nl/cve/CVE-2022-4046","fixed":"Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.","last_modified":"2026-05-29T14:06:35.326Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-04.pdf","primary_source":"","published":"2023-08-03T12:39:44.002Z"},{"affected":"< V4.10.0.0","affected_versions_present":true,"cve_id":"CVE-2023-37559","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-37559","fixed":"Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.","last_modified":"2024-10-11T18:09:05.823Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-04.pdf","primary_source":"","published":"2023-08-03T11:06:56.079Z"},{"affected":"< V4.10.0.0","affected_versions_present":true,"cve_id":"CVE-2023-37558","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-37558","fixed":"Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.","last_modified":"2024-10-11T18:09:20.780Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-04.pdf","primary_source":"","published":"2023-08-03T11:06:36.112Z"},{"affected":"< V4.10.0.0","affected_versions_present":true,"cve_id":"CVE-2023-37557","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-37557","fixed":"Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.","last_modified":"2024-10-09T20:52:16.817Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-04.pdf","primary_source":"","published":"2023-08-03T11:06:17.884Z"},{"affected":"< V4.10.0.0","affected_versions_present":true,"cve_id":"CVE-2023-37556","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-37556","fixed":"Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.","last_modified":"2024-10-09T20:52:36.722Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-04.pdf","primary_source":"","published":"2023-08-03T11:05:52.986Z"},{"affected":"< V4.10.0.0","affected_versions_present":true,"cve_id":"CVE-2023-37555","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-37555","fixed":"Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.","last_modified":"2024-10-09T20:52:51.974Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-04.pdf","primary_source":"","published":"2023-08-03T11:05:33.660Z"},{"affected":"< V4.10.0.0","affected_versions_present":true,"cve_id":"CVE-2023-37554","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-37554","fixed":"Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.","last_modified":"2024-10-11T18:09:34.979Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-04.pdf","primary_source":"","published":"2023-08-03T11:05:09.750Z"},{"affected":"< V4.10.0.0","affected_versions_present":true,"cve_id":"CVE-2023-37553","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-37553","fixed":"Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.","last_modified":"2024-10-11T18:10:16.403Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-04.pdf","primary_source":"","published":"2023-08-03T11:04:39.061Z"},{"affected":"< V4.10.0.0","affected_versions_present":true,"cve_id":"CVE-2023-37552","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-37552","fixed":"Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.","last_modified":"2024-10-11T18:10:33.714Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-04.pdf","primary_source":"","published":"2023-08-03T11:04:04.128Z"},{"affected":"< V4.10.0.0","affected_versions_present":true,"cve_id":"CVE-2023-37551","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-37551","fixed":"Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.","last_modified":"2024-10-11T18:10:51.431Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-04.pdf","primary_source":"","published":"2023-08-03T11:03:37.457Z"},{"affected":"< V4.10.0.0","affected_versions_present":true,"cve_id":"CVE-2023-37550","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-37550","fixed":"Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.","last_modified":"2024-10-11T18:11:18.756Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-04.pdf","primary_source":"","published":"2023-08-03T11:03:09.222Z"},{"affected":"< V4.10.0.0","affected_versions_present":true,"cve_id":"CVE-2023-37549","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-37549","fixed":"Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.","last_modified":"2024-10-11T18:12:01.720Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-04.pdf","primary_source":"","published":"2023-08-03T11:02:33.725Z"},{"affected":"< V4.10.0.0","affected_versions_present":true,"cve_id":"CVE-2023-37548","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-37548","fixed":"Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.","last_modified":"2024-10-11T18:12:26.294Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-04.pdf","primary_source":"","published":"2023-08-03T11:02:02.224Z"},{"affected":"< V4.10.0.0","affected_versions_present":true,"cve_id":"CVE-2023-37547","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-37547","fixed":"Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.","last_modified":"2024-10-11T18:12:55.550Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-04.pdf","primary_source":"","published":"2023-08-03T11:01:10.534Z"},{"affected":"< V4.10.0.0","affected_versions_present":true,"cve_id":"CVE-2023-37546","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-37546","fixed":"Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.","last_modified":"2024-10-11T18:14:28.818Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-04.pdf","primary_source":"","published":"2023-08-03T11:00:33.624Z"},{"affected":"< V4.10.0.0","affected_versions_present":true,"cve_id":"CVE-2023-37545","cve_url":"https://cve.blacktree.nl/cve/CVE-2023-37545","fixed":"Version 6.3.1 of Vijeo Designer includes a fix for this vulnerability and can be updated through the Schneider Electric Software Update (SESU) application. https://www.se.com/ww/en/product-range/1054-vijeodesigner-hmi-software/#software-and-firmware On the engineering workstation, update to v6.3.1 of Vijeo Designer. In order to complete the update, connect to Harmony HMI and download the project file using Vijeo Designer v6.3.1.","last_modified":"2024-10-11T18:14:47.934Z","patch_url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-192-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-192-04.pdf","primary_source":"","published":"2023-08-03T10:59:28.961Z"},{"affected":"V4.5.0.0 < V4.5.0.0","affected_versions_present":true,"cve_id":"CVE-2022-22518","cve_url":"https://cve.blacktree.nl/cve/CVE-2022-22518","fixed":"No fixed version is explicitly recorded in the structured CVE data.","last_modified":"2024-09-17T02:11:34.421Z","patch_url":"","primary_source":"","published":"2022-04-07T18:21:21.950Z"}],"source_generated_at":"2026-10-06T06:22:27.870Z","vendor":"CODESYS"}}