{"api_version":"v1","generated_at":"2026-10-09T11:25:00+00:00","product":{"cve_count":3,"evidence_gap_note":"This identity is present in BlackTree CVE records, but no product-specific publisher support or retirement history is currently registered in Lifecycle.","id":"security:cve-abb-awin-gw100-rev-2-d7b57261f720","lifecycle_state":"evidence_gap","linked_lifecycle_url":null,"name":"AWIN GW100 rev.2","next_cursor":null,"observations":[{"affected":"2.0-0; 2.0-1; 1.2-0; 1.2-1","affected_versions_present":true,"cve_id":"CVE-2025-13779","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-13779","fixed":"Do the following actions: - Stop and disconnect any AWIN gateways that are exposed directly to the Internet. - Ensure that physical controls are in place, so no unauthorized personnel can access your devices, components, peripheral equipment, and networks. - Ensure that all AWIN gateways are upgraded to the latest firmware version. Please find the latest version of firmware on the respective product Release Notes. - When remote access is required, only use secure methods. The problem is corrected in the following product versions: - AWIN GW100 rev2: v2.1-0 - AWIN GW120: v2.0-0 ABB recommends that customers contact ABB to obtain the updated firmware as soon as possible. ABB Service Support engineer shall apply the firmware update at earliest convenience.","last_modified":"2026-03-13T14:11:57.527Z","patch_url":"https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329&LanguageCode=en&DocumentPartId=&Action=Launch","primary_source":"","published":"2026-03-13T13:11:11.547Z"},{"affected":"2.0-0; 2.0-1; 1.2-0; 1.2-1","affected_versions_present":true,"cve_id":"CVE-2025-13778","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-13778","fixed":"Do the following actions: - Stop and disconnect any AWIN gateways that are exposed directly to the Internet. - Ensure that physical controls are in place, so no unauthorized personnel can access your devices, components, peripheral equipment, and networks. - Ensure that all AWIN gateways are upgraded to the latest firmware version. Please find the latest version of firmware on the respective product Release Notes. - When remote access is required, only use secure methods. The problem is corrected in the following product versions: - AWIN GW100 rev2: v2.1-0 - AWIN GW120: v2.0-0 ABB recommends that customers contact ABB to obtain the updated firmware as soon as possible. ABB Service Support engineer shall apply the firmware update at earliest convenience.","last_modified":"2026-03-13T13:35:18.364Z","patch_url":"https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329&LanguageCode=en&DocumentPartId=&Action=Launch","primary_source":"","published":"2026-03-13T13:08:40.380Z"},{"affected":"2.0-0; 2.0-1; 1.2-0; 1.2-1","affected_versions_present":true,"cve_id":"CVE-2025-13777","cve_url":"https://cve.blacktree.nl/cve/CVE-2025-13777","fixed":"Do the following actions: - Stop and disconnect any AWIN gateways that are exposed directly to the Internet. - Ensure that physical controls are in place, so no unauthorized personnel can access your devices, components, peripheral equipment, and networks. - Ensure that all AWIN gateways are upgraded to the latest firmware version. Please find the latest version of firmware on the respective product Release Notes. - When remote access is required, only use secure methods. The problem is corrected in the following product versions: - AWIN GW100 rev2: v2.1-0 - AWIN GW120: v2.0-0 ABB recommends that customers contact ABB to obtain the updated firmware as soon as possible. ABB Service Support engineer shall apply the firmware update at earliest convenience.","last_modified":"2026-03-13T13:35:36.115Z","patch_url":"https://search.abb.com/library/Download.aspx?DocumentID=4JNO000329&LanguageCode=en&DocumentPartId=&Action=Launch","primary_source":"","published":"2026-03-13T13:05:26.329Z"}],"source_generated_at":"2026-10-09T06:17:25.511Z","vendor":"ABB"}}